Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Bishop's Manor: Difference between revisions

From FireAlarmPedia
(this is fucking aden's apartment building. I regret making this...)
 
No edit summary
 
(12 intermediate revisions by 3 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FX-2000 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Year Opened: 2021
| FACP: Mircom FX-2000 <br>FACP Location: Main Entrance Vestibule<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Temporal <br>Strobes Synchronized: Yes<br />Date of last known Upgrade: N/A <br />Year Opened: 2021
|}
|}
 
'''Bishop's Manor''' is a 5-story apartment building/condominium for low income people located at 200 Nina Gardens NE, Calgary, AB. It was built in 2021, and the system is undoubtedly original.
'''Bishop's Manor''', also known by its address 200 Nina Gardens NE is a 5-story apartment building/condominium for low income people located in Bridgeland, NE Calgary. It was built in 2021, and the system is undoubtedly original.
== System Specifications (2021-present) ==
 
== System Specifications ==
 
==== FACP ====
==== FACP ====
 
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's Advanced addressable protocol, and the system coding is temporal.
The fire alarm panel is a Mircom FX-2000 installed during construction. It is located at the front entrance.
 
==== Notification Appliances ====
==== Notification Appliances ====
All common areas have System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, bilingual, set to 15cd/electromechanical).


The notification appliances are mainly System Sensor "L-Series" P2RLA (red, wall mount, English/French lettering) horn/strobes, seen throughout the building. In the units, there are System Sensor "L-Series" SWLA (white, wall mount, English/French lettering) remote strobes. Outside the entrance, there is a System Sensor "SpectrAlert Advance" SRK (red, wall mount) weatherproof remote strobe located on the left of the doors.
All units have Mircom MH-S25WA silenceable mini-horns (white, wall-mount), as well as System Sensor SRLA remote strobes (red, wall-mount).


For outdoor notification, there is a System Sensor "SpectrAlert Advance" SRKA weatherproof remote strobe (red, wall-mount) outside the main entrance.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All pull stations are Mircom MS-401AP addressable single-action pull stations.
The pull stations are all Mircom MS-401AP addressable pull stations.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
Not available at this time.
==== Modules ====
There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system's tamper and flow switches.


Not available at this time.
==== EOLs ====
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.
[[Category:Calgary]]
[[Category:Residential]]

Latest revision as of 15:39, 8 September 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Year Opened: 2021

Bishop's Manor is a 5-story apartment building/condominium for low income people located at 200 Nina Gardens NE, Calgary, AB. It was built in 2021, and the system is undoubtedly original.

System Specifications (2021-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's Advanced addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All common areas have System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, bilingual, set to 15cd/electromechanical).

All units have Mircom MH-S25WA silenceable mini-horns (white, wall-mount), as well as System Sensor SRLA remote strobes (red, wall-mount).

For outdoor notification, there is a System Sensor "SpectrAlert Advance" SRKA weatherproof remote strobe (red, wall-mount) outside the main entrance.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mircom MS-401AP addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

Not available at this time.

Modules[edit | edit source]

There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.