Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier AFP-200C <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: N/A<br />Year Opened: 2001
| FACP: Notifier SFP-400B <br />FACP Location: Electrical Room <br>System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br>Strobes Synchronized: No <br>Date of last known Upgrade: N/A<br />Year Opened: 2001
|}
|}
 
'''Fish Creek-Lacombe Station''' is an LRT station located at 14300 Shawnee Gate SW, Calgary, Alberta, Canada. It serves several communities in Southwest and Southeast Calgary. The station is mostly outdoors, but has a small building with ticket machines, plus a fire alarm system. The station was built in 2001, and the fire alarm system is original. This is also the only station on the Red line’s South leg to have a Notifier system.
‘’’’Fish Creek-Lacombe Station’’’’ is an LRT station in Calgary, Alberta. It serves several communities in Southwest and Southeast Calgary. The station is mostly outdoors, but has a small building with ticket machines, plus a fire alarm system. The station was built in 2001, and has the original system. This is also the only station on the red line’s south leg to have a Notifier system.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The station is protected by a Notifier AFP-200C addressable fire alarm system. The panel is located in an electrical room, and unconfirmed, but it is likely an AFP-200 based on the age and size of the building. The system runs on Notifier’s CLIP addressable protocol, and does code 3 in alarm.
The building is protected by a Notifier SFP-400B conventional fire alarm system. The panel is located in the electrical room at the rear of the building. The system coding is likely temporal.
 
====Notification Appliances====
====Notification Appliances====
There are only two notification appliances in the building. Both are Notifier KMS-6-24VDC motor bells (6” gong”) on Wheelock RSSP-2415W-FR strobe plates.
There are only two notification appliances in the building. Both are Notifier KMS-6-24VDC/P motor bells (6” gong”) mounted on Wheelock RSSP-2415W-FR strobe plates (15cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
Both pull stations are Notifier NFM-950B conventional single-action pull stations. These likely have Notifier MMX-101A CLIP addressable modules connected to them, as they are conventional.
Both pull stations are Notifier NFM-950B conventional single-action pull stations.
====Automatic Detection Devices====
There are System Sensor 1400A conventional 2-wire ionization smoke detectors mounted in the rafters of the building.


====Automatic Detection Devices====
==== EOLs ====
None noticed.
There are Notifier EOL-CR end of line resistor plates on all circuits.
[[Category:Calgary]]
[[Category:Train Stations]]

Latest revision as of 20:23, 27 September 2024

System Specifications
FACP: Notifier SFP-400B
FACP Location: Electrical Room
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal?
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Opened: 2001

Fish Creek-Lacombe Station is an LRT station located at 14300 Shawnee Gate SW, Calgary, Alberta, Canada. It serves several communities in Southwest and Southeast Calgary. The station is mostly outdoors, but has a small building with ticket machines, plus a fire alarm system. The station was built in 2001, and the fire alarm system is original. This is also the only station on the Red line’s South leg to have a Notifier system.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier SFP-400B conventional fire alarm system. The panel is located in the electrical room at the rear of the building. The system coding is likely temporal.

Notification Appliances[edit | edit source]

There are only two notification appliances in the building. Both are Notifier KMS-6-24VDC/P motor bells (6” gong”) mounted on Wheelock RSSP-2415W-FR strobe plates (15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

Both pull stations are Notifier NFM-950B conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are System Sensor 1400A conventional 2-wire ionization smoke detectors mounted in the rafters of the building.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all circuits.