Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

Mail is now working! Feel free to request an account. Accounts are available to invested enthusiasts/technicians in the industry. :)

ThePurpleMage's Collection: Difference between revisions

From FireAlarmPedia
(Made my collection page. Took two hours)
No edit summary
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
=== Panels (FACP) ===
=== Gone ===
{| class="wikitable"
[[Category:Facilities]]
|+
!Model
!Image
!Type
!Zone/Point Capacity
!NACs
!Coding Options
!Power Supply
!NAC Voltage
!System Line Voltage
!Synchronization Support
!Manufacturing Date
!Notes
!Origin
|-
|Edwards
 
2280
|
|Conventional
|6 Zones
|2 NACs
|None
|
|24VDC
|120VAC
|None
|1979
|My oldest  panel
|Carl
 
(Legacy)
|-
|Fire Lite
 
Miniscan 112
|
|Conventional
|4 Zones
|2 NACs
|None
|
|24VFWR
|120VAC
|None
|1984
|Lost, I can't find it
|Shane
 
(Sprouse)
|-
|Notifier/Emhart
 
Unknown Model
|
|Conventional
|1 Zone
|1 NAC
|None
|
|24VFWR
|120VAC
|None
|Unknown
|None of the LEDs work
|Shane (Sprouse)
|-
|Mirtone
70605
|
|Conventional
|1 Zone
|1 NAC
|None
|
|24VFWR
|120VAC
|None
|Unknown
|My Rarest panel. I'm the only collector to own one
|Carl (Legacy)
|-
|Notifier
AFP-200C
|
|Addressable
|99 Points (Modules)
99 Points
 
(Detectors)
|4 NACs
|Continuous, Temporal, 120BPM, California
|
|24VDC
|120VAC
|System Sensor, Wheelock, Gentex
|2002
|
|Carl
(Legacy)
|-
|EST
IO-1000
|
|Addressable
|1000
|8 NACs
|Continuous, Temporal, Custom
|
|24VFWR
|120VAC
|Genesis
|2017
|My favourite panel.
 
 
In a retrofit cabinet
|Carl
(Legacy)
|}
=== Notification Appliances ===
{| class="wikitable"
|+
!Model Number
!Images
!Quantity
!Type
!Product Line
!Voltage
!Strobe Intensity
!Sound Output
!Manufacturing Date
!Notes
!Origin
|-
|Edwards
 
439D-6AWC
|
|1
|Vibrating Bell
|
|24VDC
|
|98db
|Unknown
|
|
|-
|Simplex
 
2901 2723
|
|3
|Motor Bell
|
|24VDC
|
|Unkown
|2012
|
|
|-
|Some old horn
|
|1
|Mechanical horn
|
|12VAC
|
|133db
|Unknown
|LOUD!!!!
 
looks looks like it could have a projector
|
|-
|EST
G1-HDVM
|
|1
|Horn/Strobe
|Genesis
|24VDC
|Multi CD
|103db
|Unkown
|
|AdenK2333
|-
|EST
G1-VM
|
|2
|Remote Strobe
|Genesis
|24VDC
|Multi CD
|
|2017
|
|Carl (Lagacy)
|-
|Wheelock MT-241575W
|
|1
|Horn/Storbe
|
|24VDC
|15/75 CD
|Varying
|Unknown
|
|AdenK2333
|}
 
=== Pull Stations ===
{| class="wikitable"
|+
!Model Number
!Image
!Quantity
!Type
!Manufacturing
Date
!Notes
!Origin
|-
|Simplex
4251-20
|
|1
|Single Action
Single Stage
 
Conventional
|Unkown
|
|AdenK2333
|-
|Couch
F1GG "Chevron
|
|1
|Single Action
Single Stage
 
Conventional
|Unkown
|Broke from being slammed
|Shane (Sprouse)
|-
|Notifier
NBG12L
|
|1
|Dual Action
Single Stage
 
Conventional
|Unkown
|Was formerly and NBG12LX
|Unknown
|-
|Notifier
LNG-1R
|
|1
|Dual Action
Single Stage
 
Conventional
|Unkown
|
|YYCFireAlarmNimrod
|-
|Notifier
MPS-950B
|
|1
|Single Action
Single Stage
 
Conventional
|Unkown
|
|YYCFireAlarmNimrod
|-
|Edwards
270-SPOW
|
|1
|Single Action
Single Stage
 
Conventional
|
|Switch is no longer functional. Screw is so stripped its unusable
|Unknown
|}
 
=== Automatic Detectors ===
{| class="wikitable"
|+
!Model Number
!Image
!Quantity
!Type
!Manufacturing
Date
!Notes
!Origin
|-
|Edwards
C2M-PD
|
|1
|Photo Smoke
Conventional
|Unknown
|
|YYCFireAlarmNimrod
|-
|EST
SIGA-PD
|
|1
|Photo Smoke
Addressable
|2017
|Came brand new
|EST Tech
|-
|Vigilant
V-HRD
|
|1
|Rate of Rise Heat
Addressable
|Unkown
|
|Unknown
|}

Latest revision as of 15:09, 2 April 2023

Gone

Contents