=== Panels (FACP) ===
=== Gone ===
{| class="wikitable"
[[Category:Facilities]]
|+
!Model
!Image
!Type
!Zone/Point Capacity
!NACs
!Coding Options
!Power Supply
!NAC Voltage
!System Line Voltage
!Synchronization Support
!Manufacturing Date
!Notes
!Origin
|-
|Edwards
2280
|
|Conventional
|6 Zones
|2 NACs
|Continuous
|
|24VDC
|120VAC
|None
|1979
|My oldest panel
|Carl
(Legacy)
|-
|Fire Lite
Miniscan 112
|
|Conventional
|4 Zones
|2 NACs
|Continuous
|
|24VFWR
|120VAC
|None
|1984
|In a box of stuff that I misplaced  years ago
|Shane
(Sprouse)
|-
|Notifier/Emhart
Unknown Model
|
|Conventional
|1 Zone
|1 NAC
|Continuous
|
|24VFWR
|120VAC
|None
|Unknown
|None of the LEDs work
|Shane (Sprouse)
|-
|Mirtone
70605
|
|Conventional
|1 Zone
|1 NAC
|Continuous
|
|24VFWR
|120VAC
|None
|Unknown
|My Rarest panel. I'm the only collector to own one
|Carl (Legacy)
|-
|Notifier
AFP-200C
|
|Addressable
|99 Points (Modules)
99 Points
 
(Detectors)
|4 NACs
|Continuous, Temporal, 120BPM, California
|
|24VDC
|120VAC
|System Sensor, Wheelock, Gentex
|2002
|
|Carl
(Legacy)
|-
|EST
IO-1000
|
|Addressable
|1000
|8 NACs
|Continuous, Temporal, Coder (Custom)
|16.5 A
|24VFWR
|120VAC
|Genesis
|2019
|My favourite panel.
 
 
In a retrofit cabinet
|Carl
(Legacy)
|-
|IBM
4201-2
 
(Soon to be obtained)
|
|Coded
|N/A
|2
|4-4
|
|120VAC
|120VAC
|Npne
|1940s
|Will be my oldest panel by far
|Glenn James
(Old School Fire Alarms)
|}
=== Notification Appliances ===
{| class="wikitable"
|+
!Model Number
!Images
!Quantity
!Type
!Product Line
!Voltage
!Strobe Intensity
!Sound Output
!Manufacturing Date
!Notes
!Origin
|-
|Edwards
439D-6AWC
|
|1
|Vibrating Bell
|
|24VDC
|
|98db
|Unknown
|
|
|-
|Simplex
2901 2723
|
|3
|Motor Bell
|
|24VDC
|
|Unkown
|2012
|
|
|-
|Some old horn
|
|1
|Mechanical horn
|
|12VAC
|
|133db
|Unknown
|LOUD!!!!
looks looks like it could have a projector
|
|-
|EST
G1-HDVM
|
|1
|Horn/Strobe
|Genesis
|24VDC
|Multi CD
|103db
|Unkown
|
|AdenK2333
|-
|EST
G1-VM
|
|2
|Remote Strobe
|Genesis
|24VDC
|Multi CD
|
|2017
|
|Carl (Lagacy)
|-
|Wheelock MT-241575W
|
|1
|Horn/Storbe
|
|24VDC
|15/75 CD
|Varying
|Unknown
|
|AdenK2333
|}
=== Pull Stations ===
{| class="wikitable"
|+
!Model Number
!Image
!Quantity
!Type
!Manufacturing
Date
!Notes
!Origin
|-
|Simplex
4251-20
|
|1
|Single Action
Single Stage
 
Conventional
|Unknown
|
|AdenK2333
|-
|Couch
F1GG "Chevron"
|
|1
|Single Action
Single Stage
 
Conventional
|Unknown
|Broke from being slammed
|Shane (Sprouse)
|-
|Notifier
NBG12LX
|
|1
|Dual Action
Single Stage
 
Conventional
|Unknown
|
|Unknown
|-
|Notifier
LNG-1R
|
|1
|Dual Action
Single Stage
 
Conventional
|Unknown
|
|YYCFireAlarmNimrod
|-
|Notifier
MPS-950B
|
|1
|Single Action
Single Stage
 
Conventional
|Unknown
|
|YYCFireAlarmNimrod
|-
|Edwards
270-SPOW
|
|1
|Single Action
Single Stage
 
Conventional
|
|Switch is no longer functional. Screw is so stripped its unusable
|Unknown
|}
=== Automatic Detectors ===
{| class="wikitable"
|+
!Model Number
!Image
!Quantity
!Type
!Manufacturing
Date
!Notes
!Origin
|-
|Edwards
C2M-PD
|
|1
|Photo Smoke
Conventional
 
2-Wire
|Unknown
|
|YYCFireAlarmNimrod
|-
|EST
SIGA-PD
|
|1
|Photo Smoke
Addressable
|2017
|Came brand new
|EST Tech
|-
|Vigilant
V-HRD
|
|1
|Rate of Rise Heat
Addressable
|Unknown
|
|Unknown
|-
|Notifier
FSP-851
|
|1
|Photo Smoke
Addressable
|2018?
|Came new old stock
|Phuntington
|-
|Notifier
FSP-951
|
|1
|Photo Smoke
Addressable
|2022
|Came brand new
|Phuntington
|}