1939 30 St SW, Calgary: Difference between revisions

From FireAlarmPedia
(Page revamped. This one didn't need much work.)
(Cleaned up infobox, added EOLs.)
 
(5 intermediate revisions by 2 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FA-1000  
| FACP: Mircom FA-1000 <br>FACP Location: Main Entrance<br />System Type: Single-Stage Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br>System Coding: Temporal <br />Strobes Synchronized: No <br>Date of last known Upgrade: N/A <br />Year Opened: 2008
FACP Location: Main Entrance<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR
 
System Coding: Temporal <br />Date of last known Upgrade: N/A <br />Year Opened: 2008
|}
|}
'''1939 30 St SW''' is a 3-story apartment building in Killarney/Glengarry, SW Calgary. It was built in 2008, and has its original system. This condominium has no notification appliances in the units.  
'''1939 30 St SW''' is a 3-story apartment building in Killarney/Glengarry, SW Calgary. It was built in 2008, and has its original system. This condominium has no notification appliances in the units.  
Line 21: Line 18:
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.
None noticed.
[[Category:Facilities]]
 
==== EOLs ====
There are Mircom MP-300 end of line resistor plates on all circuits.
[[Category:Calgary]]
[[Category:Residential]]

Latest revision as of 13:02, 19 August 2024

System Specifications
FACP: Mircom FA-1000
FACP Location: Main Entrance
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Opened: 2008

1939 30 St SW is a 3-story apartment building in Killarney/Glengarry, SW Calgary. It was built in 2008, and has its original system. This condominium has no notification appliances in the units.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FA-1000 conventional fire alarm system. The panel is located at the main entrance. The system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are Mircom "Select-A-Horn/Strobe" FHS-240R horn/strobes (red, wall-mount, 15cd). The units have residential smoke alarms in them; there are no notification appliances in the units.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mircom MS-401 conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

None noticed.

EOLs[edit | edit source]

There are Mircom MP-300 end of line resistor plates on all circuits.