Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Royal Tyrrell Museum: Difference between revisions

From FireAlarmPedia
mNo edit summary
No edit summary
 
(9 intermediate revisions by 3 users not shown)
Line 1: Line 1:
'''Royal Tyrrell Museum''' is a paleontology and dinosaur museum in Drumheller, located at 1500 N Dinosaur Trail. It is also Canada's only museum that is only for prehistoric life. The museum is also a big tourist attraction for Alberta. It was built in 1985, but has had its current fire alarm system since 2016 after an expansion.
'''Royal Tyrrell Museum''' is a paleontology and dinosaur museum located at 1500 N Dinosaur Trail, in Drumheller, Alberta, Canada. It is Canada's only museum exclusively showcasing prehistoric life. The museum opened in 1985, and received total fire alarm system upgrades in 2003 and 2016.
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
|-
|-
! System Specifications
! System Specifications
|-
|-
| FACP: Edwards EST3
| FACP: Edwards EST3 <br>FACP Location: Main Entrance <br>System Type: Single-Stage Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis<br />Date of last known Upgrade: 2016<br />Year Opened: 1985
FACP Location: Main Entrance
System Type: Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC
 
System Coding: Temporal
 
Strobes Synchronized: Yes<br />Date of last known Upgrade: 2016<br />Year Opened: 1985
|}
|}
== System Specifications ==
== System Specifications (2016-present) ==
==== FACP ====
==== FACP ====
The museum is protected by an Edwards EST3 addressable fire alarm system. The panel is located at the main entrance. The system runs EST's Signature-series addressable protocol, and the system coding is temporal.
The building is protected by an Edwards EST3 addressable fire alarm system. The panel is located in the lobby. It is equipped with the LCDXL1 display and an ENVOY graphic annunciator. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.
==== Notification Appliances ====
==== Notification Appliances ====
Most notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no FIRE, set to 15cd), mounted on EST G1RT-FIRE trim plates. The Cretaceous Gardens have EST "Genesis" WG4RN-HVMC weatherproof horn/strobes (red, no FIRE). For outdoor notification, there is an EST CS405-7A-T (red, 15/75cd) remote strobe by the entrance.
Most notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd), mounted on EST G1RT-FIRE trim plates; others are not mounted on trim plates.
 
The Cretaceous Gardens have Edwards WG4RN-HVMC weatherproof horn/strobes (red, no marking, set to 60cd).  
 
For outdoor notification, there is an EST CS405-7A-T (red, 15/75cd) weatherproof remote strobe by the main entrance.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.
All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the building, mounted on SIGA-SB bases.
There are EST SIGA2-PS addressable photoelectric smoke detectors in some areas, mounted on SIGA-SB bases.  
== Former System Specifications ==
 
The air handling units have EST "SuperDuct" SIGA-SD addressable photoelectric duct smoke detectors.
 
There is also a sprinkler system.
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
There are also EST SIGA-CR relay modules serving various purposes.
 
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
 
== Former System Specifications (2003-2016) ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
|-
|-
Line 29: Line 39:
|  
|  
|-
|-
| FACP: Siemens MXL
| FACP: Siemens MXL <br>FACP Location: Near Main Entrance<br />System Type: Two-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: 20BPM (Alert) <br>Temporal (Alarm) <br>Strobes Synchronized: Yes, Siemens<br />Date of last known Upgrade: N/A <br>Year Installed: 2003<br />Year Decommissioned: 2016
FACP Location: Near Main Entrance<br />System Type: Addressable (Two-Stage) <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC  
 
System Coding: 20BPM (First Stage)
 
Temporal (GA)<br />Date of last known Upgrade: N/A <br />Year Decommissioned: 2016
|}
|}
==== FACP ====
==== FACP ====
The building was protected by a Siemens MXL addressable fire alarm system. The panel was located near the main entrance. The system was configured for two stage operation. The coding was 20BPM in first stage, followed by temporal in general alarm.
The building was protected by a Siemens MXL addressable fire alarm system. The panel was located near the main entrance. The system ran Siemens' FirePrint addressable protocol, and was configured for two stage operation. The alert signal coding was 20BPM, and the alarm signal was temporal.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances were Siemens U-MMT-MCS-W-B (white, bilingual, wall-mount, multi-candela) multi tone horn/strobes. They were likely set to the horn tone.
All notification appliances were Siemens U-MMT-MCS-W-B (white, bilingual, wall-mount, multi-candela) multi tone horn/strobes. They were likely set to the horn tone.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations were Siemens MSI-30B addressable two-stage pull stations.
All pull stations were Siemens MSI-30B addressable two-stage single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.
None noticed. There was a sprinkler system.
==== Modules ====
There were Siemens TRI-M addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
==== EOLs ====
There were Siemens EL-300C end-of-line resistor plates on all sprinkler and signal circuits.
 
== Bonus Information ==
== Bonus Information ==
Above the outdoor strobe, there is an Edwards "Adaptabel" 333D single-stroke bell (6" gong), left over from the original Edwards 6500 system. It is disconnected.
Above the outdoor strobe, there is an Edwards "Adaptabel" 333D single-stroke bell (6" gong), left over from the original Edwards 6500 system. It is disconnected.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Alberta]]

Latest revision as of 22:26, 11 October 2024

Royal Tyrrell Museum is a paleontology and dinosaur museum located at 1500 N Dinosaur Trail, in Drumheller, Alberta, Canada. It is Canada's only museum exclusively showcasing prehistoric life. The museum opened in 1985, and received total fire alarm system upgrades in 2003 and 2016.

System Specifications
FACP: Edwards EST3
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: 2016
Year Opened: 1985

System Specifications (2016-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an Edwards EST3 addressable fire alarm system. The panel is located in the lobby. It is equipped with the LCDXL1 display and an ENVOY graphic annunciator. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

Most notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd), mounted on EST G1RT-FIRE trim plates; others are not mounted on trim plates.

The Cretaceous Gardens have Edwards WG4RN-HVMC weatherproof horn/strobes (red, no marking, set to 60cd).

For outdoor notification, there is an EST CS405-7A-T (red, 15/75cd) weatherproof remote strobe by the main entrance.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA2-PS addressable photoelectric smoke detectors in some areas, mounted on SIGA-SB bases.

The air handling units have EST "SuperDuct" SIGA-SD addressable photoelectric duct smoke detectors.

There is also a sprinkler system.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are also EST SIGA-CR relay modules serving various purposes.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.

Former System Specifications (2003-2016)[edit | edit source]

System Specifications
FACP: Siemens MXL
FACP Location: Near Main Entrance
System Type: Two-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: 20BPM (Alert)
Temporal (Alarm)
Strobes Synchronized: Yes, Siemens
Date of last known Upgrade: N/A
Year Installed: 2003
Year Decommissioned: 2016

FACP[edit | edit source]

The building was protected by a Siemens MXL addressable fire alarm system. The panel was located near the main entrance. The system ran Siemens' FirePrint addressable protocol, and was configured for two stage operation. The alert signal coding was 20BPM, and the alarm signal was temporal.

Notification Appliances[edit | edit source]

All notification appliances were Siemens U-MMT-MCS-W-B (white, bilingual, wall-mount, multi-candela) multi tone horn/strobes. They were likely set to the horn tone.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were Siemens MSI-30B addressable two-stage single-action pull stations.

Automatic Detection Devices[edit | edit source]

None noticed. There was a sprinkler system.

Modules[edit | edit source]

There were Siemens TRI-M addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There were Siemens EL-300C end-of-line resistor plates on all sprinkler and signal circuits.

Bonus Information[edit | edit source]

Above the outdoor strobe, there is an Edwards "Adaptabel" 333D single-stroke bell (6" gong), left over from the original Edwards 6500 system. It is disconnected.