McDonald's (39 Avenue): Difference between revisions

From FireAlarmPedia
(I don't like JCI.)
 
No edit summary
 
(3 intermediate revisions by 2 users not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Simplex 4007ES <br /> FACP Location: Kitchen <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SmartSync <br />Date of last known Upgrade: 2016 <br />Year Opened: 1988
| FACP: Simplex 4007ES <br />FACP Location: Kitchen <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Date of last known Upgrade: 2016 <br />Year Opened: 1988
|}
|}
 
'''McDonald’s''' is the world’s second largest fast food chain. This particular restaurant is located at 3912 Macleod Trail SE, in Calgary, Alberta, Canada. The restaurant opened in 1988, and the fire alarm system was upgraded in 2016.
'''McDonald’s''' is the world’s second largest fast food chain. This particular restaurant is located at 3912 Macleod Trail Southeast, in Calgary, Alberta, Canada. The restaurant opened in 1988, and the fire alarm system was upgraded in 2016. The system is serviced by Johnson Controls.
 
==System Specifications (2016-present)==
==System Specifications (2016-present)==
====FACP====
====FACP====
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the kitchen. The system coding is temporal.
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the kitchen. The system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is a Simplex 4606-9202 annunciator in the main entrance vestibule.
There is a Simplex 4606-9202 annunciator in the main entrance vestibule.
====Notification Appliances====
====Notification Appliances====
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations but one are Edwards 270-SPO conventional single-action pull stations. There is an Edwards 270-SPOB conventional bilingual single-action pull station by the washrooms as a deficiency replacement.
All pull stations but one are Edwards 270-SPO conventional single-action pull stations. There is an Edwards 270-SPOB conventional bilingual single-action pull station by the washrooms as a deficiency replacement.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
==== EOLs ====
There are Simplex 2081-9040C end of line resistor plates on all circuits.
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Restaurants]]

Latest revision as of 10:57, 12 October 2024

System Specifications
FACP: Simplex 4007ES
FACP Location: Kitchen
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SmartSync
Date of last known Upgrade: 2016
Year Opened: 1988

McDonald’s is the world’s second largest fast food chain. This particular restaurant is located at 3912 Macleod Trail SE, in Calgary, Alberta, Canada. The restaurant opened in 1988, and the fire alarm system was upgraded in 2016.

System Specifications (2016-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the kitchen. The system coding is temporal.

Annunciators[edit | edit source]

There is a Simplex 4606-9202 annunciator in the main entrance vestibule.

Notification Appliances[edit | edit source]

All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations but one are Edwards 270-SPO conventional single-action pull stations. There is an Edwards 270-SPOB conventional bilingual single-action pull station by the washrooms as a deficiency replacement.

Automatic Detection Devices[edit | edit source]

None noticed.

EOLs[edit | edit source]

There are Simplex 2081-9040C end of line resistor plates on all circuits.