Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Water Tower Grill & Bar: Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
(2 intermediate revisions by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Kidde VS4  
| FACP: Kidde VS4
FACP Location: Main Entrance<br />System Type:Addressable-Hybrid<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR  
FACP Location: Main Entrance<br />System Type: Single-Stage Conventional<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR  


System Coding: Temporal
System Coding: Temporal


Strobes Synchronized: Yes<br />Date of last known Upgrade: 2018-2020 <br />Year Opened: 1959 (as a water tower) <br> 2003 (as a restaurant)
Strobes Synchronized: Yes, Genesis<br />Date of last known Upgrade: 2021<br />Year Opened: 1959 (as a water tower) <br> 2003 (as a restaurant)
|}
|}
The '''Water Tower Grill & Bar''' is a restaurant in Lethbridge, AB. It is located near the neighborhood of Glendale in between North and South Lethbridge. The restaurant started off as a water tower in 1959, converted into a restaurant with a great view in 2003. The fire alarm panel was replaced in 2021.
The '''Water Tower Grill & Bar''' is a restaurant located at 103 Mayor Magrath Drive S, Lethbridge, Alberta. The restaurant started off as a water tower in 1959, converted into a restaurant in 2003. The fire alarm system was upgraded in 2003, with a panel replacement in 2021.
== System Specifications ==
== System Specifications (2021-present) ==
==== FACP ====
==== FACP ====
The restaurant is protected by a Kidde VS4 addressable fire alarm system. The panel is located at the main entrance. The system runs Kidde's GSA addressable protocol, and the system coding is temporal.
The restaurant is protected by a Kidde VS4 conventional fire alarm system. The panel is located at the main entrance. The system coding is temporal.
 
The VS4 replaced an EST FireShield FS1004G in 2021.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no FIRE, set to 15cd).  
All notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).  
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are Edwards 270-SPO conventional single-action pull stations. These are likely connected to Kidde GSA-CT1 addressable modules.
All pull stations are Edwards 270-SPO conventional single-action pull stations.  
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.
None noticed.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Restaurants]]
[[Category:Lethbridge]]

Latest revision as of 20:23, 14 October 2024

System Specifications
FACP: Kidde VS4

FACP Location: Main Entrance
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage:24VFWR

System Coding: Temporal

Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: 2021
Year Opened: 1959 (as a water tower)
2003 (as a restaurant)

The Water Tower Grill & Bar is a restaurant located at 103 Mayor Magrath Drive S, Lethbridge, Alberta. The restaurant started off as a water tower in 1959, converted into a restaurant in 2003. The fire alarm system was upgraded in 2003, with a panel replacement in 2021.

System Specifications (2021-present)[edit | edit source]

FACP[edit | edit source]

The restaurant is protected by a Kidde VS4 conventional fire alarm system. The panel is located at the main entrance. The system coding is temporal.

The VS4 replaced an EST FireShield FS1004G in 2021.

Notification Appliances[edit | edit source]

All notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Edwards 270-SPO conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

None noticed.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all circuits.