| FACP: Notifier AFP-200C <br /> FACP Location: Main EntranceSystem Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: No <br> Date of last known Upgrade: N/A <br />Year Opened: 2000
| FACP: Notifier AFP-200<br /> FACP Location: Main Entrance Vestibule<br>System Type: Single-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: No <br> Date of last known Upgrade: N/A <br />Year Opened: 2000
|}
|}
 
'''Comfort Inn''' is a hotel chain owned by Choice hotels. They are headquartered in Rockville, Maryland, and have been around since 1939. This particular hotel is located at 2369 Banff Trail Northwest, in Calgary, Alberta, Canada. The building opened in 2000, and the fire alarm system is original.
'''Comfort Inn''' is a hotel chain owned by Choice hotels. They are headquartered in Rockville, Maryland, and have been around since 1939. This particular hotel is located at 2369 Banff Trail Northwest, in Calgary, Alberta, Canada. The building opened in 2000, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier AFP-200C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s CLIP addressable protocol, and the system coding is temporal.
The building is protected by a Notifier AFP-200 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s CLIP addressable protocol, and the system coding is temporal.
 
=====Booster Panels=====
=====Booster Panels=====
There is a Notifier FCPS-24S8C 8 amp booster power supply mounted next to the main FACP.
There is a Notifier FCPS-24 booster power supply mounted next to the main FACP.
 
====Notification Appliances====
====Notification Appliances====
All common areas have System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd).  The guest rooms have System Sensor S24110WA remote strobes (white, wall-mount, 110cd) paired with System Sensor "Mini-Alert" PA400RA mini-horns (red, wall-mount).
All common areas have System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd).  


The guest rooms have System Sensor S24110WA remote strobes (white, wall-mount, 110cd) paired with System Sensor "Mini-Alert" PA400RA mini-horns (red, wall-mount).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier NFM-950B conventional single-action pull stations.  All stations are wired to Notifier MMX-101A addressable monitor modules, located directly behind each station.
All pull stations are Notifier NFM-950B conventional single-action pull stations, wired to Notifier MMX-101A addressable monitor modules.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier CPX-551A addressable ionization smoke detectors throughout the hotel, mounted on Notifier BX501 bases.
There are Notifier CPX-551A addressable ionization smoke detectors throughout the hotel, mounted on Notifier BX501 bases.
[[Category:Facilitie]
 
==== Modules ====
There are Notifier MMX-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
There are Notifier CMX-2A addressable relay modules serving various purposes.
 
==== EOLs ====
There are Notifier EOL-CR end of line resistor plates on all sprinkler and Class B signal circuits.
[[Category:Calgary]]
[[Category:Hotels]]

Latest revision as of 06:16, 24 September 2024

System Specifications
FACP: Notifier AFP-200
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Opened: 2000

Comfort Inn is a hotel chain owned by Choice hotels. They are headquartered in Rockville, Maryland, and have been around since 1939. This particular hotel is located at 2369 Banff Trail Northwest, in Calgary, Alberta, Canada. The building opened in 2000, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier AFP-200 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s CLIP addressable protocol, and the system coding is temporal.

Booster Panels[edit | edit source]

There is a Notifier FCPS-24 booster power supply mounted next to the main FACP.

Notification Appliances[edit | edit source]

All common areas have System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd).

The guest rooms have System Sensor S24110WA remote strobes (white, wall-mount, 110cd) paired with System Sensor "Mini-Alert" PA400RA mini-horns (red, wall-mount).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NFM-950B conventional single-action pull stations, wired to Notifier MMX-101A addressable monitor modules.

Automatic Detection Devices[edit | edit source]

There are Notifier CPX-551A addressable ionization smoke detectors throughout the hotel, mounted on Notifier BX501 bases.

Modules[edit | edit source]

There are Notifier MMX-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are Notifier CMX-2A addressable relay modules serving various purposes.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all sprinkler and Class B signal circuits.