'''YYCsFireAlarmNimrod's Basement (name may be subject to change)''' is a basement in Calgary. It has a mini fire alarm system owned and serviced by [[User:Yycsfirealarmnimrod|User:YYCsFireAlarmNimrod]].  
{| cellspacing="5" cellpadding="0" style="margin: 0em 0em 1em 0em; border: 1px solid #1DA0E7;  background: #B3DDF4; width: 100%"
| '''''This is a hobby system and is not powered on 24/7 and therefore does not provide any reliable fire protection. This page is for demonstration purposes only.'''''
|}
[[Category:Hobby]]
{| style="float:right;border:2px solid black"
|-
!System Specifications
|-
|
|-
|FACP: Notifier AFP-200C<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC
System Type: Addressable (Hybrid Manner)<br />Date of last upgrade: 2022<br />Year Built: 2003
|}
'''NOTE:''' ''This page is being heavily edited due to a panel change in this fire alarm system. It is also updated every time he gets a new fire alarm device.


'''YYCsFireAlarmNimrod's Basement (name may be subject to change)''' is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by [[User:Yycsfirealarmnimrod|User:YYCsFireAlarmNimrod]].
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The current FACP in this basement is a Notifier AFP-200C addressable fire alarm panel. It was made in 2003, and was previously in use at [[40 Sunpark Plaza SE]]. The panel was removed due to NAC troubles, but the culprit was found to have been bent prongs on the horn/strobe terminals. This panel is in immaculate condition, and is fully functional, with no troubles or any other issues. This is the third panel this system has had since it was installed in August 2020. The previous panel was a Simplex 4010, and the original panel was a Fire-Lite MS-4. The system runs Notifier's CLIP addressable protocol. When in alarm, the system does march time.


The fire alarm panel is a Fire-Lite MS-4 conventional panel. It was previously owned by [[User:AdenK2333]] and [[User:Twentytwo22]]. It was previously used in the [[Barndominium]].
This panel may be replaced with a Notifier NFS2-3030C in the coming weeks.


==== Notification Appliances ====
==== Notification Appliances ====
 
The notification appliances are currently a Simplex 2901-9720 motor bell (6"), along with the following devices being wired as strobes, with all horn/strobes having the horn disconnected: Siemens ZR-MC-W-B, Wheelock MT-241575W-FR, Edwards 757-5A-T, System Sensor SRA, Kidde "Genesis" EG1R-VM, Edwards 892-2B, Simplex 4903-9219, and System Sensor P4RLA.  
The only notification appliances are frequently swapped out.  The devices that are most commonly used are a Gentex GEC3-24WR Commander 3 horn/strobe, and a Simplex 2901-9720.  The -9720 came out of [RT Alderman School].
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
The current pull stations vary, but these are accurate as of 2/28/2022. The bottom left of the board has a Notifier N-MPS-SA addressable single-action pull station. Right above the N-MPS-SA is a Notifier N-MPS-2A addressable two-stage pull station, mounted on a Simplex backbox. The two-stage switch on this pull station is wired to trip the "disco lights", which are unsynchronized strobes that serve as party lights. This pull station is also equipped with a Notifier MPS-LP dual-action conversion kit. Next to the N-MPS-2A is a Pyr-A-Larm MS-51 bilingual conventional single-action pull station. This pull station is wired into a Notifier FMM-101A addressable module from the mid 2000s. Next to the MS-51 is a Notifier LNG-1R conventional dual-action pull station. This pull station is wired into a Notifier MMX-101A addressable module, which will likely be upgraded to an FMM-101A if the panel is replaced. Below the LNG-1R is a Siemens MS-53C two-stage single-action pull station. Only the pull station is hooked up; the GA switch is not in use. This pull station is wired into a Notifier FMM-1A addressable module, which was chosen in favor of an FMM-101A due to a lack of wire length, and only having 4" backboxes at the time of installation.
The pull stations are a Mircom MS-401, and a Simplex 2099-9201 (4251-20). The Mircom was bought brand new in August 2020, and the Simplex came out of [[R.T. Alderman School]].
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There is currently only one detector on this system. It is a Notifier FSL-751A VIEW (Very Intelligent Early Warning) laser smoke detector. It was removed from the Enmax headquarters in Calgary.
The only automatic detection device is a Simplex 2098-9110 2-wire ionization smoke detector. This smoke detector was used previously, it came out of [[R.T. Alderman School]].
Bonus Info: The JCI tech known as Vic said to Yycsfirealarmnimrod that this detector "belonged to the garbage can". Naturally, Yycsfirealarmnimrod put the detector in his backpack before anyone noticed.
== Videos ==
Videos of this system will be uploaded on his channel: https://www.youtube.com/c/ExistentCanadianObject <br>
Fire alarm going off for a test: https://www.youtube.com/watch?v=lVfJF4ezMEM

Latest revision as of 16:32, 16 January 2023

This is a hobby system and is not powered on 24/7 and therefore does not provide any reliable fire protection. This page is for demonstration purposes only.
System Specifications
FACP: Notifier AFP-200C
System Line Voltage: 120VAC
NAC Voltage: 24VDC

System Type: Addressable (Hybrid Manner)
Date of last upgrade: 2022
Year Built: 2003

NOTE: This page is being heavily edited due to a panel change in this fire alarm system. It is also updated every time he gets a new fire alarm device.

YYCsFireAlarmNimrod's Basement (name may be subject to change) is a basement in Calgary, built in 2003. It has a mini fire alarm system owned and serviced by User:YYCsFireAlarmNimrod.

System Specifications[edit | edit source]

FACP[edit | edit source]

The current FACP in this basement is a Notifier AFP-200C addressable fire alarm panel. It was made in 2003, and was previously in use at 40 Sunpark Plaza SE. The panel was removed due to NAC troubles, but the culprit was found to have been bent prongs on the horn/strobe terminals. This panel is in immaculate condition, and is fully functional, with no troubles or any other issues. This is the third panel this system has had since it was installed in August 2020. The previous panel was a Simplex 4010, and the original panel was a Fire-Lite MS-4. The system runs Notifier's CLIP addressable protocol. When in alarm, the system does march time.

This panel may be replaced with a Notifier NFS2-3030C in the coming weeks.

Notification Appliances[edit | edit source]

The notification appliances are currently a Simplex 2901-9720 motor bell (6"), along with the following devices being wired as strobes, with all horn/strobes having the horn disconnected: Siemens ZR-MC-W-B, Wheelock MT-241575W-FR, Edwards 757-5A-T, System Sensor SRA, Kidde "Genesis" EG1R-VM, Edwards 892-2B, Simplex 4903-9219, and System Sensor P4RLA.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The current pull stations vary, but these are accurate as of 2/28/2022. The bottom left of the board has a Notifier N-MPS-SA addressable single-action pull station. Right above the N-MPS-SA is a Notifier N-MPS-2A addressable two-stage pull station, mounted on a Simplex backbox. The two-stage switch on this pull station is wired to trip the "disco lights", which are unsynchronized strobes that serve as party lights. This pull station is also equipped with a Notifier MPS-LP dual-action conversion kit. Next to the N-MPS-2A is a Pyr-A-Larm MS-51 bilingual conventional single-action pull station. This pull station is wired into a Notifier FMM-101A addressable module from the mid 2000s. Next to the MS-51 is a Notifier LNG-1R conventional dual-action pull station. This pull station is wired into a Notifier MMX-101A addressable module, which will likely be upgraded to an FMM-101A if the panel is replaced. Below the LNG-1R is a Siemens MS-53C two-stage single-action pull station. Only the pull station is hooked up; the GA switch is not in use. This pull station is wired into a Notifier FMM-1A addressable module, which was chosen in favor of an FMM-101A due to a lack of wire length, and only having 4" backboxes at the time of installation.

Automatic Detection Devices[edit | edit source]

There is currently only one detector on this system. It is a Notifier FSL-751A VIEW (Very Intelligent Early Warning) laser smoke detector. It was removed from the Enmax headquarters in Calgary. Bonus Info: The JCI tech known as Vic said to Yycsfirealarmnimrod that this detector "belonged to the garbage can". Naturally, Yycsfirealarmnimrod put the detector in his backpack before anyone noticed.

Videos[edit | edit source]

Videos of this system will be uploaded on his channel: https://www.youtube.com/c/ExistentCanadianObject
Fire alarm going off for a test: https://www.youtube.com/watch?v=lVfJF4ezMEM