| FACP: Mircom FX-2000 <br /> FACP Location: Main Lobby <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: | | FACP: Mircom FX-2000 <br /> FACP Location: Main Lobby <br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: No <br />Date of last known Upgrade: N/A <br />Year Opened: 2015 | ||
|} | |} | ||
'''Comfort Inn & Suites''' is a chain of hotels owned by Choice Hotels. The chain is headquartered in Rockville, Maryland, USA, and has locations worldwide. This particular hotel is located at 203 19 Avenue, in Nisku, Alberta, Canada. The hotel opened in 2015, and the fire alarm system is original. | |||
'''Comfort Inn & Suites''' is a chain of hotels owned by Choice Hotels. | |||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Mircom FX-2000 addressable fire alarm system. | The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main lobby, next to the main entrance. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
=====Common Areas===== | =====Common Areas===== | ||
All common areas except the pool area have System Sensor “SpectrAlert Advance” P2RA-B horn/strobes (red, wall-mount, set to 15cd, Bilingual lettering). | All common areas except the pool area have System Sensor “SpectrAlert Advance” P2RA-B horn/strobes (red, wall-mount, set to 15cd, Bilingual lettering). The pool area has System Sensor P2RKA weatherproof horn/strobes (red, wall-mount, set to 15cd). | ||
=====Guest Rooms===== | =====Guest Rooms===== | ||
All guest rooms have Mircom MH-S25WA silenceable mini-horns (white, wall-mount). | All guest rooms have Mircom MH-S25WA silenceable mini-horns (white, wall-mount). | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Mircom MS-401AD addressable single-action pull stations. | All pull stations are Mircom MS-401AD addressable single-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Mircom MIX-2251B addressable photoelectric smoke detectors throughout the common areas of the hotel, mounted on System Sensor B210LPA low-profile bases. | There are Mircom MIX-2251B addressable photoelectric smoke detectors throughout the common areas of the hotel, mounted on System Sensor B210LPA low-profile bases. There is also a wet sprinkler system with waterflow detection protecting the hotel. | ||
====Modules==== | ====Modules==== | ||
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. | There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. | ||
[[] | |||
There are Mircom MIX-M500RA addressable relay modules serving various purposes. | |||
There are System Sensor M500XA isolator modules on the SLC. | |||
==== EOLs ==== | |||
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits. | |||
[[Category:Alberta]] | |||
[[Category:Hotels]] |
Latest revision as of 18:10, 23 September 2024
System Specifications |
---|
FACP: Mircom FX-2000 FACP Location: Main Lobby System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: No Date of last known Upgrade: N/A Year Opened: 2015 |
Comfort Inn & Suites is a chain of hotels owned by Choice Hotels. The chain is headquartered in Rockville, Maryland, USA, and has locations worldwide. This particular hotel is located at 203 19 Avenue, in Nisku, Alberta, Canada. The hotel opened in 2015, and the fire alarm system is original.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main lobby, next to the main entrance. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
Common Areas[edit | edit source]
All common areas except the pool area have System Sensor “SpectrAlert Advance” P2RA-B horn/strobes (red, wall-mount, set to 15cd, Bilingual lettering). The pool area has System Sensor P2RKA weatherproof horn/strobes (red, wall-mount, set to 15cd).
Guest Rooms[edit | edit source]
All guest rooms have Mircom MH-S25WA silenceable mini-horns (white, wall-mount).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Mircom MS-401AD addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Mircom MIX-2251B addressable photoelectric smoke detectors throughout the common areas of the hotel, mounted on System Sensor B210LPA low-profile bases. There is also a wet sprinkler system with waterflow detection protecting the hotel.
Modules[edit | edit source]
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Mircom MIX-M500RA addressable relay modules serving various purposes.
There are System Sensor M500XA isolator modules on the SLC.
EOLs[edit | edit source]
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.