| FACP: EST QuickStart QS1 <br /> FACP Location: Electrical Room, Platform Level <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, EST Self-Sync <br />Date of last known Upgrade: 2000s <br />Year Opened: 1981
| FACP: EST QuickStart QS1 <br /> FACP Location: Electrical Room, Platform Level <br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, EST Self-Sync <br />Date of last known Upgrade: 2000s <br />Year Opened: 1981
|}
|}


Line 25: Line 25:


====Automatic Detection Devices====
====Automatic Detection Devices====
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the station, mounted on EST SIGA-SB bases. The station is not equipped with a sprinkler system.
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the station, mounted on EST SIGA-SB bases.
[[]
 
====EOLs====
There are Edwards EOL-P1 end of line resistor plates on all signal circuits.
[[Category:Calgary]]
[[Category:Train Stations]]

Latest revision as of 18:58, 26 September 2024

System Specifications
FACP: EST QuickStart QS1
FACP Location: Electrical Room, Platform Level
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, EST Self-Sync
Date of last known Upgrade: 2000s
Year Opened: 1981

Erlton/Stampede Station is an LRT station located at 2408 3A Street Southeast, in Calgary, Alberta, Canada. The station primarily serves the south half of Stampede Park, and the neighborhood of Erlton. The station opened in 1981, and was expanded to accommodate 4-car trains in 2011. The fire alarm system was upgraded in the 2000s, and no original devices remain.

System Specifications (2000s-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel is located in the main electrical room, which is accessible via the tracks. The system runs EST’s Signature addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is an EST QSA-1-S annunciator on the mezzanine level. The annunciator is equipped with an EST QS1-CPU-1 control card, and an SL30L zone annunciation card.

Notification Appliances[edit | edit source]

All notification appliances are Edwards MB10-24 motor bells (10” gong) mounted on Edwards 403-5A-R strobe plates (15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA-PS addressable photoelectric smoke detectors throughout the station, mounted on EST SIGA-SB bases.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all signal circuits.