Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FX-2000 <br /> FACP Location: Unknown <br />System Type: Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br /> System Coding: Temporal<br />Date of last known Upgrade: 2000s<br />Year Opened: 1970
| FACP: Mircom FX-2000 <br /> FACP Location: Unknown <br />System Type: Single-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br /> System Coding: Temporal<br />Date of last known Upgrade: 2000s<br />Year Opened: 1970
|}
|}
'''Garden Towers''' is an apartment building located at 909 7 Avenue Southwest, in Calgary, Alberta, Canada. The building opened in 1970, and the fire alarm system was upgraded in the 2000s.  
'''Garden Towers''' is an apartment building located at 909 7 Avenue Southwest, in Calgary, Alberta, Canada. The building opened in 1970, and the fire alarm system was upgraded in the 2000s.  
Line 19: Line 19:
====Automatic Detection Devices====
====Automatic Detection Devices====
To be added later.
To be added later.
[[Category:Calgary]]
[[Category:Residential]]

Latest revision as of 10:15, 28 September 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Date of last known Upgrade: 2000s
Year Opened: 1970

Garden Towers is an apartment building located at 909 7 Avenue Southwest, in Calgary, Alberta, Canada. The building opened in 1970, and the fire alarm system was upgraded in the 2000s.

System Specifications (2000s-present)[edit | edit source]

Please note that this page is incomplete. This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

Most notification appliances are Mircom BL-10B motor bells (10” gong). The commercial units on the ground floor have Mircom BL-6B motor bells (6” gong).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

To be added later.