Plasti-Fab Plant 23: Difference between revisions

From FireAlarmPedia
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Notifier NFS2-640C <br />FACP Location: Main Entrance <br />System Type: Addressable...")
 
No edit summary
 
(One intermediate revision by one other user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS2-640C <br />FACP Location: Main Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2022 <br />Year Opened: 2006
| FACP: Notifier NFS2-640C <br />FACP Location: Main Entrance <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2022 <br />Year Opened: 2006
|}
|}
 
'''Plasti-Fab''' is a company specializing in styrofoam insulation. This page will cover Plant 23, located at 718 McCool Street, in Crossfield, Alberta, Canada. The plant opened in 2006, and the fire alarm system is mostly original.
'''Plasti-Fab''' is a company specializing in styrofoam insulation. This page will cover Plant 23, located at 718 McCool Street, in Crossfield, Alberta, Canada. The plant opened in 2006, and the fire alarm system is mostly original.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier NFS2-640C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
The building is protected by a Notifier NFS2-640C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
 
=====Annunciators=====
=====Annunciators=====
There is a Notifier LCD2-80 annunciator in the plant control room of Plant 24.
There is a Notifier LCD2-80 annunciator in the plant control room of Plant 24.
====Notification Appliances====
====Notification Appliances====
All notification appliances are Notifier KMS-10-24A motor bells (10” gong) mounted on Wheelock RSSP-24MCW strobe plates (set to 15cd).
All notification appliances are Notifier KMS-10-24A motor bells (10” gong) mounted on Wheelock RSSP-24MCW strobe plates (set to 15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Notifier MPS-950B conventional single-action pull stations. All stations have Notifier FMM-101A addressable monitor modules attached to them.
All pull stations are Notifier MPS-950B conventional single-action pull stations. All stations have Notifier FMM-101A addressable monitor modules attached to them.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
The boiler room has Notifier FST-851A addressable 135°F fixed-temperature heat detectors. The kitchen and janitor closet have Notifier FST-851RA addressable 135°F fixed/rate-of-rise heat detectors. The electrical room and compressor room have Notifier FSP-851A addressable photoelectric smoke detectors. All detectors are mounted on Notifier B710LPA bases. The building is equipped with a sprinkler system.
The boiler room has Notifier FST-851A addressable 135°F fixed-temperature heat detectors. The kitchen and janitor closet have Notifier FST-851RA addressable 135°F fixed/rate-of-rise heat detectors. The electrical room and compressor room have Notifier FSP-851A addressable photoelectric smoke detectors. All detectors are mounted on Notifier B710LPA bases. The building is equipped with a sprinkler system.
 
====Modules====
====Modules====
There are Notifier FMM-101A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier FMM-101A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
==== EOLs ====
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Alberta]]
[[Category:Industrial]]

Latest revision as of 22:33, 9 October 2024

System Specifications
FACP: Notifier NFS2-640C
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2022
Year Opened: 2006

Plasti-Fab is a company specializing in styrofoam insulation. This page will cover Plant 23, located at 718 McCool Street, in Crossfield, Alberta, Canada. The plant opened in 2006, and the fire alarm system is mostly original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS2-640C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier LCD2-80 annunciator in the plant control room of Plant 24.

Notification Appliances[edit | edit source]

All notification appliances are Notifier KMS-10-24A motor bells (10” gong) mounted on Wheelock RSSP-24MCW strobe plates (set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier MPS-950B conventional single-action pull stations. All stations have Notifier FMM-101A addressable monitor modules attached to them.

Automatic Detection Devices[edit | edit source]

The boiler room has Notifier FST-851A addressable 135°F fixed-temperature heat detectors. The kitchen and janitor closet have Notifier FST-851RA addressable 135°F fixed/rate-of-rise heat detectors. The electrical room and compressor room have Notifier FSP-851A addressable photoelectric smoke detectors. All detectors are mounted on Notifier B710LPA bases. The building is equipped with a sprinkler system.

Modules[edit | edit source]

There are Notifier FMM-101A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.