Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

McDonald's (Sparrow Drive): Difference between revisions

From FireAlarmPedia
(Fucking infoboxes)
No edit summary
 
(One intermediate revision by one other user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Edwards FireShield FSP502G <br /> FACP Location: Unknown <br /> System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br />Date of last known Upgrade: 2018 <br />Year Opened: 1981
| FACP: Edwards FireShield Plus FSP502G <br /> FACP Location: Unknown <br /> System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br />Date of last known Upgrade: 2018 <br />Year Opened: 1981
|}
|}
'''McDonald's''' is the world’s largest fast food restaurant chain.  They are headquartered in Chicago, Illinois, USA, and have over 40,000 locations globally.  This particular restaurant is located at 6504 Sparrow Drive, in Leduc, Alberta, Canada.  The restaurant opened in 1981, and was renovated in 2018.  The fire alarm system is from the renovation, but the pull stations remain original.
'''McDonald's''' is the world’s largest fast food restaurant chain.  They are headquartered in Chicago, Illinois, USA, and have over 40,000 locations globally.  This particular restaurant is located at 6504 Sparrow Drive, in Leduc, Alberta, Canada.  The restaurant opened in 1981, and was renovated in 2018.  The fire alarm system is from the renovation, but the pull stations remain original.
==System Specifications (2018-present)==
==System Specifications (2018-present)==
Please note that some system information is unconfirmed.  This page should not be used for official purposes.
Please note that some system information is unconfirmed.  This page should not be used for official purposes.
====FACP====
====FACP====
The building is protected by an Edwards FireShield FSP502G conventional fire alarm system.  The panel location is unknown.  The system coding is likely temporal.
The building is protected by an Edwards FireShield Plus FSP502G conventional fire alarm system.  The panel location is unknown.  The system coding is likely temporal.
====Notification Appliances====
====Notification Appliances====
All notification appliances are Edwards MB10-24 motor bells (10” gong).
All notification appliances are Edwards MB10-24 motor bells (10” gong).
Line 29: Line 28:
| FACP: Edwards 1527 <br /> FACP Location: Unknown <br /> System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Continuous <br />Date of last known Upgrade: 1990s <br />Year Decommissioned: 2018
| FACP: Edwards 1527 <br /> FACP Location: Unknown <br /> System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Continuous <br />Date of last known Upgrade: 1990s <br />Year Decommissioned: 2018
|}
|}
====FACP====
====FACP====
The building was protected by an Edwards 1527 conventional fire alarm system.  The panel location was unknown.  The system coding was continuous.
The building was protected by an Edwards 1527 conventional fire alarm system.  The panel location was unknown.  The system coding was continuous.
Line 39: Line 37:
====Automatic Detection Devices====
====Automatic Detection Devices====
Unknown.
Unknown.
[[Category:Alberta]]
[[Category:Restaurants]]

Latest revision as of 21:09, 25 May 2024

System Specifications
FACP: Edwards FireShield Plus FSP502G
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Date of last known Upgrade: 2018
Year Opened: 1981

McDonald's is the world’s largest fast food restaurant chain.  They are headquartered in Chicago, Illinois, USA, and have over 40,000 locations globally.  This particular restaurant is located at 6504 Sparrow Drive, in Leduc, Alberta, Canada.  The restaurant opened in 1981, and was renovated in 2018.  The fire alarm system is from the renovation, but the pull stations remain original.

System Specifications (2018-present)[edit | edit source]

Please note that some system information is unconfirmed.  This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by an Edwards FireShield Plus FSP502G conventional fire alarm system.  The panel location is unknown.  The system coding is likely temporal.

Notification Appliances[edit | edit source]

All notification appliances are Edwards MB10-24 motor bells (10” gong).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are the original Edwards 274-111 conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

Unknown at this time.

System Specifications (1981-2018)[edit | edit source]

System Specifications
FACP: Edwards 1527
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous
Date of last known Upgrade: 1990s
Year Decommissioned: 2018

FACP[edit | edit source]

The building was protected by an Edwards 1527 conventional fire alarm system.  The panel location was unknown.  The system coding was continuous.

Notification Appliances[edit | edit source]

The main dining room had an Edwards “Durabel” 6100D vibrating bell (6” gong).  The playplace had a Mirtone 74330 vibrating bell (10” gong), installed as a deficiency replacement.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were Edwards 274-111 conventional single-action pull stations.  These remain in use on the new system.

Automatic Detection Devices[edit | edit source]

Unknown.