Holiday Inn Express & Suites Springfield North: Difference between revisions

From FireAlarmPedia
mNo edit summary
No edit summary
 
Line 20: Line 20:
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building. These are mounted on Edwards SIGA-SB bases in the common areas, and on Edwards SIGA-AB4G-LF low-frequency sounder bases in all guest rooms. There is also a sprinkler system with waterflow detection.
There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building. These are mounted on Edwards SIGA-SB bases in the common areas, and on Edwards SIGA-AB4G-LF low-frequency sounder bases in all guest rooms. There is also a sprinkler system with waterflow detection.
==== Modules ====
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
[[Category:Missouri]]
[[Category:Hotels]]

Latest revision as of 16:53, 25 May 2024

System Specifications
FACP: Edwards iO1000
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: N/A
Year Opened: 2019

Holiday Inn Express is a chain of budget hotels owned by IHG. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 3050 North Kentwood Avenue, in Springfield, Missouri, USA. The hotel opened in 2019, and the fire alarm system is original.

System Specifications (2019-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by an Edwards iO1000 addressable fire alarm system. The panel location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is an Edwards RLCD-C annunciator behind the front desk.

Notification Appliances[edit | edit source]

There are Edwards “Genesis” GC-HDVM horn/strobes (white, ceiling-mount, set to 15cd) throughout the common areas. All guest rooms have Edwards G1F-VM remote strobes (white, wall-mount, set to 110cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-278 addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Edwards SIGA-PD addressable photoelectric smoke detectors throughout the building. These are mounted on Edwards SIGA-SB bases in the common areas, and on Edwards SIGA-AB4G-LF low-frequency sounder bases in all guest rooms. There is also a sprinkler system with waterflow detection.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.