Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Holiday Inn Florence: Difference between revisions

From FireAlarmPedia
(EDWARDS)
 
No edit summary
 
Line 7: Line 7:
| FACP: Edwards EST3? <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: N/A <br />Year Opened: 2010
| FACP: Edwards EST3? <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: N/A <br />Year Opened: 2010
|}
|}
 
'''Holiday Inn''' is a chain of hotels owned by Intercontinental. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 7905 Freedom Way, in Florence, Kentucky, USA. The hotel opened in 2010, and the fire alarm system is original.
'''Holiday Inn''' is a chain of hotels owned by Intercontinental. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 7905 Freedom Way, in Florence, Kentucky, USA. The hotel opened in 2010, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
Please note that the panel details are unconfirmed. This page should not be used for official purposes.
Please note that the panel details are unconfirmed. This page should not be used for official purposes.
====FACP====
====FACP====
The building is protected by an Edwards addressable fire alarm system. The panel is likely an Edwards EST3, and the location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.
The building is protected by an Edwards addressable fire alarm system. The panel is likely an Edwards EST3, and the location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are Edwards “Genesis” G1F-HDVM horn/strobes (white, wall-mount, FIRE marking, set to 15cd).
All notification appliances are Edwards “Genesis” G1F-HDVM horn/strobes (white, wall-mount, FIRE marking, set to 15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-278 addressable dual-action pull stations.
All pull stations are EST SIGA-278 addressable dual-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the building. <br>These are mounted on EST SIGA-SB4 bases in common areas, and on EST SIGA-AB4G sounder bases in all guest rooms.
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the building. <br>These are mounted on EST SIGA-SB4 bases in common areas, and on EST SIGA-AB4G sounder bases in all guest rooms.
 
====Modules====
====Modules====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
[[Category:Kentucky]]
[[Category:Hotels]]

Latest revision as of 17:57, 25 May 2024

System Specifications
FACP: Edwards EST3?
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: N/A
Year Opened: 2010

Holiday Inn is a chain of hotels owned by Intercontinental. The chain is headquartered in Denham, England, and has locations globally. This particular hotel is located at 7905 Freedom Way, in Florence, Kentucky, USA. The hotel opened in 2010, and the fire alarm system is original.

System Specifications[edit | edit source]

Please note that the panel details are unconfirmed. This page should not be used for official purposes.

FACP[edit | edit source]

The building is protected by an Edwards addressable fire alarm system. The panel is likely an Edwards EST3, and the location is unknown. The system runs Edwards’ Signature addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are Edwards “Genesis” G1F-HDVM horn/strobes (white, wall-mount, FIRE marking, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-278 addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA-PS addressable photoelectric smoke detectors throughout the building.
These are mounted on EST SIGA-SB4 bases in common areas, and on EST SIGA-AB4G sounder bases in all guest rooms.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.