1291 Gordon St, Guelph: Difference between revisions

From FireAlarmPedia
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FX-2000 <br />FACP Location: Electrical Room? <br />System Type: Addressable <...")
 
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FX-2000 <br />FACP Location: Electrical Room? <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br />Date of last known Upgrade: N/A <br />Year Opened: 2015
| FACP: Mircom FX-2000 <br />FACP Location: Electrical Room? <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br /> Strobes Synchronized: N/A <br>Date of last known Upgrade: N/A <br />Year Opened: 2015
|}
|}
'''1291 Gordon St''' is the address given to a 3-story apartment building in Guelph, Ontario. It was built in 2015, and the fire alarm system is original.  
'''1291 Gordon St''' is the address given to a 3-story apartment building in Guelph, Ontario. It was built in 2015, and the fire alarm system is original.  
== System Specifications (2015-present) ==
== System Specifications (2015-present) ==
==== FACP ====
==== FACP ====
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Mircom’s CLIP addressable protocol, and the system coding is likely temporal.
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Mircom’s CLIP addressable protocol, and the system coding is likely temporal.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are Mircom MH-25R mini-horns (red). These are also in units.
All notification appliances are Mircom MH-25R mini-horns (red). These are also in units.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are Mircom MS-401AD addressable single-action pull stations.
All pull stations are Mircom MS-401AD addressable single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases.
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout, mounted on System Sensor B710LPA bases.
 
==== Modules ====
==== Modules ====
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  <br>There are System Sensor M500XA isolator modules on the SLC.


There are Mircom MIX-M501MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
==== EOLs ====
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.
[[Category:Residential]]

Latest revision as of 10:58, 19 August 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Electrical Room?
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal?
Strobes Synchronized: N/A
Date of last known Upgrade: N/A
Year Opened: 2015

1291 Gordon St is the address given to a 3-story apartment building in Guelph, Ontario. It was built in 2015, and the fire alarm system is original.

System Specifications (2015-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Mircom’s CLIP addressable protocol, and the system coding is likely temporal.

Notification Appliances[edit | edit source]

All notification appliances are Mircom MH-25R mini-horns (red). These are also in units.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases.

Modules[edit | edit source]

There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are System Sensor M500XA isolator modules on the SLC.

EOLs[edit | edit source]

There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.