More actions
(Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FX-2000 <br />FACP Location: Electrical Room? <br />System Type: Addressable <...") |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Mircom FX-2000 <br />FACP Location: Electrical Room? <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br />Date of last known Upgrade: N/A <br />Year Opened: 2015 | | FACP: Mircom FX-2000 <br />FACP Location: Electrical Room? <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br /> Strobes Synchronized: N/A <br>Date of last known Upgrade: N/A <br />Year Opened: 2015 | ||
|} | |} | ||
'''1291 Gordon St''' is the address given to a 3-story apartment building in Guelph, Ontario. It was built in 2015, and the fire alarm system is original. | '''1291 Gordon St''' is the address given to a 3-story apartment building in Guelph, Ontario. It was built in 2015, and the fire alarm system is original. | ||
== System Specifications (2015-present) == | == System Specifications (2015-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Mircom’s CLIP addressable protocol, and the system coding is likely temporal. | The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Mircom’s CLIP addressable protocol, and the system coding is likely temporal. | ||
==== Notification Appliances ==== | ==== Notification Appliances ==== | ||
All notification appliances are Mircom MH-25R mini-horns (red). These are also in units. | All notification appliances are Mircom MH-25R mini-horns (red). These are also in units. | ||
=== Initiating Devices === | === Initiating Devices === | ||
==== Pull Stations ==== | ==== Pull Stations ==== | ||
All pull stations are Mircom MS-401AD addressable single-action pull stations. | All pull stations are Mircom MS-401AD addressable single-action pull stations. | ||
==== Automatic Detection Devices ==== | ==== Automatic Detection Devices ==== | ||
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases. | |||
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout, mounted on System Sensor | |||
==== Modules ==== | ==== Modules ==== | ||
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches. <br>There are System Sensor M500XA isolator modules on the SLC. | |||
There are Mircom | ==== EOLs ==== | ||
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits. | |||
[[Category:Residential]] |
Latest revision as of 10:58, 19 August 2024
System Specifications |
---|
FACP: Mircom FX-2000 FACP Location: Electrical Room? System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal? Strobes Synchronized: N/A Date of last known Upgrade: N/A Year Opened: 2015 |
1291 Gordon St is the address given to a 3-story apartment building in Guelph, Ontario. It was built in 2015, and the fire alarm system is original.
System Specifications (2015-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is likely located in an electrical room. The system runs Mircom’s CLIP addressable protocol, and the system coding is likely temporal.
Notification Appliances[edit | edit source]
All notification appliances are Mircom MH-25R mini-horns (red). These are also in units.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Mircom MS-401AD addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Mircom MIX-2251BA addressable photoelectric smoke detectors throughout, mounted on System Sensor B210LPA bases.
Modules[edit | edit source]
There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are System Sensor M500XA isolator modules on the SLC.
EOLs[edit | edit source]
There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.