The Home Depot is an American hardware store franchise. This particular store was built in 2005, and is located in the Shepard area in SE Calgary (more commonly known as South Trail Crossing or 130th avenue, or simply 130th.The system, is original, and, besides the panel, is essentially the same as the Shawnessy location.
{| style="float:right;border:2px solid black"
|-
! System Specifications
|-
|
|-
| FACP: Notifier AFP-200
FACP Location: unknown<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC
 
System Coding: Temporal
 
Strobes Synchronized: No<br />Date of last known Upgrade: 2010s <br />Year Opened: 2005
|}
The Home Depot is an American hardware store franchise. This particular store was built in 2005, and is located at 5125 126 Ave SE, in the Shepard area in SE Calgary. The system is original, and besides the addressable fire alarm panel, is essentially the same as the [[The Home Depot (Shawnessy)|Shawnessy location]].
==System Specifications==
==System Specifications==
====FACP====
===FACP===
The fire alarm panel is a Notifier AFP-200, judging by the LCD2-80 annunciator, and the "All Systems Normal" status on the annunciator.  It is original.
The store is protected by a Notifier AFP-200C addressable fire alarm system. The panel location is unknown. The system runs Notifier's CLIP addressable protocol, and the system coding is temporal.
==== Annunciators ====
There is a Notifier LCD2-80 annunciator at the entrance.
====Notification Appliances====
====Notification Appliances====
The main notification appliances are System Sensor "SpectrAlert" P1224MC (red, wall) horn/strobes. The restrooms have System Sensor "SpectrAlert" S1224MC remote strobes.  The garden centre has a System Sensor "SpectrAlert Advance" P2R (red, wall) horn/strobe behind a weatherproof cover. It is unknown why it is mounted like that, perhaps a P2RK wasn't available?
The notification appliances are mainly the original System Sensor "SpectrAlert" P2415A (red, wall-mount, 15cd) horn/strobes.  
 
The restrooms have System Sensor S2415A (red, wall) remote strobes.


The garden center has a System Sensor "SpectrAlert Advance" P4RA (red, wall-mount, 4-wire) horn/strobe behind a weatherproof cover, as a deficiency replacement of a System Sensor P1224MCKA (red, wall-mount) weatherproof horn/strobe in the 2010s. It is unknown why it is mounted like that, but it is possible that a P4RKA was not available.
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The main pull stations are Notifier MPS-950B. Replacements for failed pulls include Tyco/Grinnell MS-401, and Simplex MS-301C.
The main pull stations are Notifier MPS-950B conventional pull stations.  
 
There are Simplex MS-301C pull stations, installed as deficiency replacements.
 
There are also a few Tyco/Grinnell MS-401GR pull stations, also installed as deficiency replacements.
 
All pull stations are wired to Notifier MMX-101A addressable modules, located directly behind the stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
Waterflow, no detectors present.
==== Modules ====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
 
==== EOLs ====
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Retail Stores]]

Latest revision as of 11:59, 14 October 2024

System Specifications
FACP: Notifier AFP-200

FACP Location: unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC

System Coding: Temporal

Strobes Synchronized: No
Date of last known Upgrade: 2010s
Year Opened: 2005

The Home Depot is an American hardware store franchise. This particular store was built in 2005, and is located at 5125 126 Ave SE, in the Shepard area in SE Calgary. The system is original, and besides the addressable fire alarm panel, is essentially the same as the Shawnessy location.

System Specifications[edit | edit source]

FACP[edit | edit source]

The store is protected by a Notifier AFP-200C addressable fire alarm system. The panel location is unknown. The system runs Notifier's CLIP addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier LCD2-80 annunciator at the entrance.

Notification Appliances[edit | edit source]

The notification appliances are mainly the original System Sensor "SpectrAlert" P2415A (red, wall-mount, 15cd) horn/strobes.

The restrooms have System Sensor S2415A (red, wall) remote strobes.

The garden center has a System Sensor "SpectrAlert Advance" P4RA (red, wall-mount, 4-wire) horn/strobe behind a weatherproof cover, as a deficiency replacement of a System Sensor P1224MCKA (red, wall-mount) weatherproof horn/strobe in the 2010s. It is unknown why it is mounted like that, but it is possible that a P4RKA was not available.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The main pull stations are Notifier MPS-950B conventional pull stations.

There are Simplex MS-301C pull stations, installed as deficiency replacements.

There are also a few Tyco/Grinnell MS-401GR pull stations, also installed as deficiency replacements.

All pull stations are wired to Notifier MMX-101A addressable modules, located directly behind the stations.

Automatic Detection Devices[edit | edit source]

Waterflow, no detectors present.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.