Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

40 Sunpark Plaza SE: Difference between revisions

From FireAlarmPedia
No edit summary
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS-320C
| FACP: Notifier NFS-320C <br>FACP Location: Main Entrance<br />System Type: Single-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: Temporal <br>Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020 <br />Year Opened: 2004
FACP Location: Main Entrance<br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC
 
System Coding: Temporal
 
Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020 <br />Year Opened: 2004
|}
|}
'''40 Sunpark Plaza SE''' is the address given to a mixed-use 3-story office complex located in the Sundance neighborhood of Calgary, Alberta, Canada. The first floor contains a doctor's office, a Shoppers Drug Mart, and formerly an optometrist. It was built in 2004, and the current fire alarm system was installed in 2020.
'''40 Sunpark Plaza SE''' is the address given to a mixed-use 3-story office complex located in the Sundance neighborhood of Calgary, Alberta, Canada. The first floor contains a doctor's office, a Shoppers Drug Mart, and formerly an optometrist. It was built in 2004, and the current fire alarm system was installed in 2020.
Line 23: Line 18:
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the facility, mounted on System Sensor B210LPA low-profile bases.
There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the facility, mounted on System Sensor B210LPA low-profile bases.
====Modules====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches. <br>There are Notifier FRM-1A addressable relay modules serving various purposes.
====EOLs====
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.
==System Specifications (original system) (2004-2020)==
==System Specifications (original system) (2004-2020)==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 30: Line 29:
|  
|  
|-
|-
| FACP: Notifier AFP-200
| FACP: Notifier AFP-200 <br>FACP Location: Main Entrance<br />System Type: Single-Stage Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC <br>System Coding: Temporal <br>Strobes Synchronized: No<br />Date of last known Upgrade: late 2010s <br />Year Decomissioned: 2020
FACP Location: Main Entrance<br />System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VDC
 
System Coding: Temporal
 
Strobes Synchronized: No<br />Date of last known Upgrade: late 2010s <br />Year Decomissioned: 2020
|}
|}
====FACP====
====FACP====
The building was protected by a Notifier AFP-200 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Notifier's CLIP addressable protocol, and the system coding was temporal. This panel is now owned by [[User:Yycsfirealarmnimrod|TwentyThree33]]. and is now in use in [[YYCsFireAlarmNimrod's Basemen]. The panel is fully functional, and was replaced due to NAC troubles. However the culprit was found to have been faulty horn/strobe installation.
The building was protected by a Notifier AFP-200 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Notifier's CLIP addressable protocol, and the system coding was temporal. This panel is now owned by [[User:Yycsfirealarmnimrod|TwentyThree33]]]. The panel is fully functional, and was replaced due to NAC troubles. However the culprit was found to have been faulty horn/strobe installation.
====Notification Appliances====
====Notification Appliances====
All notification appliances were System Sensor "SpectrAlert Advance" P2RA horn/strobes (red, wall-mount, set to 15cd). These were installed in 2015, and replaced System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). There was also a Mircom "Select-A-Horn/Strobe" FHS-340R horn/strobe (red, wall-mount, set to 15cd/broadband) in the atrium, which was also replaced in 2013.  
All notification appliances were System Sensor "SpectrAlert Advance" P2RA horn/strobes (red, wall-mount, set to 15cd). These were installed in 2015, and replaced System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). There was also a Mircom "Select-A-Horn/Strobe" FHS-340R horn/strobe (red, wall-mount, set to 15cd/broadband) in the atrium, which was also replaced in 2013.  
Line 46: Line 40:
====Automatic Detection Devices====
====Automatic Detection Devices====
There were Notifier FSP-851A addressable photoelectric smoke detectors located throughout the building, mounted on System Sensor B210LPA low-profile bases. These may be in use on the current system, however this is unconfirmed.
There were Notifier FSP-851A addressable photoelectric smoke detectors located throughout the building, mounted on System Sensor B210LPA low-profile bases. These may be in use on the current system, however this is unconfirmed.
====Modules====
There were Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches. <br>There were Notifier FRM-1A addressable relay modules serving various purposes.
====EOLs====
There were Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.
[[]
[[]
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Commercial]]
[[Category:Commercial]]

Latest revision as of 13:00, 25 August 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: 2020
Year Opened: 2004

40 Sunpark Plaza SE is the address given to a mixed-use 3-story office complex located in the Sundance neighborhood of Calgary, Alberta, Canada. The first floor contains a doctor's office, a Shoppers Drug Mart, and formerly an optometrist. It was built in 2004, and the current fire alarm system was installed in 2020.

System Specifications (2020-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. This system runs Notifier's FlashScan addressable protocol, and the system coding is temporal. The permit issued for the upgrade was "Fire Alarm Repair (Sunpark Professional Building)" on May 28, 2020.

Notification Appliances[edit | edit source]

Most notification appliances are System Sensor P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd). Some areas such as washrooms have System Sensor SRLA remote strobes (red, wall-mount, bilingual lettering, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the facility, mounted on System Sensor B210LPA low-profile bases.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Notifier FRM-1A addressable relay modules serving various purposes.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.

System Specifications (original system) (2004-2020)[edit | edit source]

System Specifications
FACP: Notifier AFP-200
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage:24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: late 2010s
Year Decomissioned: 2020

FACP[edit | edit source]

The building was protected by a Notifier AFP-200 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Notifier's CLIP addressable protocol, and the system coding was temporal. This panel is now owned by TwentyThree33]. The panel is fully functional, and was replaced due to NAC troubles. However the culprit was found to have been faulty horn/strobe installation.

Notification Appliances[edit | edit source]

All notification appliances were System Sensor "SpectrAlert Advance" P2RA horn/strobes (red, wall-mount, set to 15cd). These were installed in 2015, and replaced System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). There was also a Mircom "Select-A-Horn/Strobe" FHS-340R horn/strobe (red, wall-mount, set to 15cd/broadband) in the atrium, which was also replaced in 2013.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were Notifier MPS-950B conventional single-action pull stations, All pull stations were wired to Notifier FMM-101A addressable modules, which were located directly behind each station.

Automatic Detection Devices[edit | edit source]

There were Notifier FSP-851A addressable photoelectric smoke detectors located throughout the building, mounted on System Sensor B210LPA low-profile bases. These may be in use on the current system, however this is unconfirmed.

Modules[edit | edit source]

There were Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There were Notifier FRM-1A addressable relay modules serving various purposes.

EOLs[edit | edit source]

There were Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits. [[]