In October 2018, there was a career fair held at the [[BMO Centre]]. There were two tables regarding fire alarm work, one was for CFAA (Canadian Fire Alarm Association) and one was for a Tyco fire alarm career. Both of those had mini fire alarm systems for demonstration purposes only.
In October 2018, there was a career fair held at the [[BMO Centre]]. There were two tables regarding fire alarm work, one was for CFAA (Canadian Fire Alarm Association) and one was for a Tyco fire alarm career. Both of those had temporary mini fire alarm systems for demonstration purposes only.<br>''Note: These systems were for demonstration purposes only, and did not actually serve to warn people of fire. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.''
<br>  
Note: These systems were for demo purposes only, and did not actually serve to warn people of fire.  
 
== System Specifications (CFAA) ==
== System Specifications (CFAA) ==
 
{| style="float:right;border:2px solid black"
|-
! System Specifications
|-
|
|-
| FACP: Notifier NFS-320SYS <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS
|}
==== FACP ====
==== FACP ====
 
The panel for this demo system was a Notifier NFS-320SYS addressable fire alarm system. The system ran Notifier's FlashScan addressable protocol, and the system coding was temporal. It was specially programmed for the demo system.  
The fire alarm control panel for this station was a Notifier NFS-320SYS. It was specially programmed for the demo system.  
 
==== Notification Appliances ====
==== Notification Appliances ====
Both notification appliances were from System Sensor's "SpectrAlert Advance" line of products.


The notification appliances consisted of a System Sensor "SpectrAlert Advance" MHWZA (white, silenceable) mini-horn and a System Sensor "SpectrAlert Advance" P2R (red, wall) horn/strobe, set to 15/75 cd and low volume. The mini-horn would sound when the pull station was activated, and the horn/strobe would activate when the automatic detection devices were activated. Each horn does code-3.
There was a System Sensor MHWZA mini-horn (white, silenceable), which sounded when the pull station was activated.


There was also a System Sensor P2RA horn/strobe (red, wall-mount, set to low volume, 15/75cd), which would sound if a smoke or heat detector was activated.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
The pull station was a Notifier NBG-12LX addressable dual action pull station. When it was activated, it would sound the mini-horn.
The only pull station was a Notifier NBG-12LX addressable dual action pull station. When it was activated, it would sound the mini-horn.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
The automatic detection devices consisted of two Notifier FSP-851A addressable photoelectric smoke detectors, and a Notifier FST-851RA thermal addressable heat detector. When one of these were activated, the horn/strobe would go off.
The automatic detection devices consisted of two Notifier FSP-851 addressable photoelectric smoke detectors, and a Notifier FST-851R thermal addressable heat detector. When one of these were activated, the horn/strobe would go off.
== System Specifications (Tyco) ==
 
{| style="float:right;border:2px solid black"
== System Specifications (Tyco) ==  
|-
 
! System Specifications
|-
|
|-
| FACP: Simplex 4007ES <br /><br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 29VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, IDNAC
|}
==== FACP ====
==== FACP ====
 
The panel for this demo system was a Simplex 4007ES addressable fire alarm system. The system ran Simplex's IDNet addressable initiating protocol and IDNAC addressable signaling protocol, and the system coding was temporal.
The fire alarm control panel for this demo system was a Simplex 4007ES. It also had a Simplex 4606-9202 touchscreen color screen annunciator right next to it. When in alarm, both strobes are synchronized, and the horn does code-3.
===== Annunciators =====
 
There was a Simplex 4606-9202 touchscreen color screen annunciator right next to the panel, and a graphic annunciator underneath.  
==== Notification Appliances ====
==== Notification Appliances ====
Both notification appliances are from Simplex's "TrueAlert ES" line of addressable products.


The notification appliances consisted of a Simplex "TrueAlert ES" 59AV-WRF (red, wall) addressable LED horn/strobe and a Simplex "TrueAlert ES" 59VO-WRF (red, wall) addressable LED strobe. The horn/strobe had tape covering the horn grill, due to the loudness of the alarm and the fact that it was for an expo.  
They were a Simplex 59AV-WRF addressable LED horn/strobe (red, wall-mount, set to 15cd), and a Simplex 59VO-WRF addressable remote strobe (red, wall-mount, set to 15cd). The horn/strobe had tape covering the horn grill, due to the loudness of the alarm and the fact that it was for an expo.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull station was a Simplex 4099-9004 addressable single action pull station.
==== Automatic Detection Devices ====
The automatic detection devices consisted of a Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detector, a Simplex 4098-9733 addressable fixed-temperature/rate-of-rise heat detector, and a Simplex 4098-9754 addressable multi-sensor heat and smoke detector; this was mounted on a 4098-9795 sounder base. There were also modules and relays for simulating a waterflow system.
==== Modules ====
There were Simplex 4090-9001 addressable monitor modules supervising simulated sprinkler flow and tamper switches.


The only pull station consisted of a Simplex 4099-9004 IDNet addressable single-action T-bar pull station with an LED.
There was also a Simplex 4090-9002 addressable relay module simulating an HVAC fan shutdown.  
 
==== Automatic Detection Devices ====


The automatic detection devices consisted of a Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detector, a Simplex 4098-9403 addressable fixed-temperature heat detector, and a Simplex 4098-9754 addressable multi-sensor heat and smoke detector.
There was also a 4090-9116 IDNet isolator module on the SLC.

Latest revision as of 12:39, 15 April 2024

In October 2018, there was a career fair held at the BMO Centre. There were two tables regarding fire alarm work, one was for CFAA (Canadian Fire Alarm Association) and one was for a Tyco fire alarm career. Both of those had temporary mini fire alarm systems for demonstration purposes only.
Note: These systems were for demonstration purposes only, and did not actually serve to warn people of fire. NEVER pull a fire alarm unless there is actually a fire emergency. The staff on this wiki are not responsible for your actions if you get fined.

System Specifications (CFAA)[edit | edit source]

System Specifications
FACP: Notifier NFS-320SYS
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SS

FACP[edit | edit source]

The panel for this demo system was a Notifier NFS-320SYS addressable fire alarm system. The system ran Notifier's FlashScan addressable protocol, and the system coding was temporal. It was specially programmed for the demo system.

Notification Appliances[edit | edit source]

Both notification appliances were from System Sensor's "SpectrAlert Advance" line of products.

There was a System Sensor MHWZA mini-horn (white, silenceable), which sounded when the pull station was activated.

There was also a System Sensor P2RA horn/strobe (red, wall-mount, set to low volume, 15/75cd), which would sound if a smoke or heat detector was activated.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull station was a Notifier NBG-12LX addressable dual action pull station. When it was activated, it would sound the mini-horn.

Automatic Detection Devices[edit | edit source]

The automatic detection devices consisted of two Notifier FSP-851A addressable photoelectric smoke detectors, and a Notifier FST-851RA thermal addressable heat detector. When one of these were activated, the horn/strobe would go off.

System Specifications (Tyco)[edit | edit source]

System Specifications
FACP: Simplex 4007ES

System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 29VDC
System Coding: Temporal
Strobes Synchronized: Yes, IDNAC

FACP[edit | edit source]

The panel for this demo system was a Simplex 4007ES addressable fire alarm system. The system ran Simplex's IDNet addressable initiating protocol and IDNAC addressable signaling protocol, and the system coding was temporal.

Annunciators[edit | edit source]

There was a Simplex 4606-9202 touchscreen color screen annunciator right next to the panel, and a graphic annunciator underneath.

Notification Appliances[edit | edit source]

Both notification appliances are from Simplex's "TrueAlert ES" line of addressable products.

They were a Simplex 59AV-WRF addressable LED horn/strobe (red, wall-mount, set to 15cd), and a Simplex 59VO-WRF addressable remote strobe (red, wall-mount, set to 15cd). The horn/strobe had tape covering the horn grill, due to the loudness of the alarm and the fact that it was for an expo.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull station was a Simplex 4099-9004 addressable single action pull station.

Automatic Detection Devices[edit | edit source]

The automatic detection devices consisted of a Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detector, a Simplex 4098-9733 addressable fixed-temperature/rate-of-rise heat detector, and a Simplex 4098-9754 addressable multi-sensor heat and smoke detector; this was mounted on a 4098-9795 sounder base. There were also modules and relays for simulating a waterflow system.

Modules[edit | edit source]

There were Simplex 4090-9001 addressable monitor modules supervising simulated sprinkler flow and tamper switches.

There was also a Simplex 4090-9002 addressable relay module simulating an HVAC fan shutdown.

There was also a 4090-9116 IDNet isolator module on the SLC.