| FACP: Siemens TXL-1000 <br />FACP Location: Electrical Room? <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br />Date of last known Upgrade: Late 2010s <br />Year Opened: 1990
| FACP: Siemens TXL-1000 <br />FACP Location: Electrical Room? <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal? <br />Date of last known Upgrade: Late 2010s <br />Year Opened: 1990
|}
|}
'''Bertram Place''' is a 55+ apartment building located 1385 Bertram St, Kelowna, BC. It was built in 1990, and the fire alarm system is mostly original, with parts replaced as deficiencies occur.
'''Bertram Place''' is a 55+ apartment building located 1385 Bertram St, Kelowna, BC. It was built in 1990, and the fire alarm system is mostly original, with parts replaced as deficiencies occur.
Line 21: Line 21:
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Edwards 6250C conventional ionization smoke detectors throughout. <br> Some areas, including all units, have Edwards 281C conventional 135-degree fixed-temperature/rate-of-rise heat detectors. <br> There are System Sensor 5601A conventional 135-degree fixed-temperature/rate-of-rise heat detectors as deficiency replacements.
There are Edwards 6250C conventional ionization smoke detectors throughout. <br> Some areas, including all units, have Edwards 281C conventional 135-degree fixed-temperature/rate-of-rise heat detectors. <br> There are System Sensor 5601A conventional 135-degree fixed-temperature/rate-of-rise heat detectors as deficiency replacements.
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all circuits.
[[Category:British Columbia]]
[[Category:British Columbia]]
[[Category:Residential]]
[[Category:Residential]]

Latest revision as of 15:18, 8 September 2024

System Specifications
FACP: Siemens TXL-1000
FACP Location: Electrical Room?
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal?
Date of last known Upgrade: Late 2010s
Year Opened: 1990

Bertram Place is a 55+ apartment building located 1385 Bertram St, Kelowna, BC. It was built in 1990, and the fire alarm system is mostly original, with parts replaced as deficiencies occur.

System Specifications (1990-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Siemens TXL-1000 conventional fire alarm system. The panel is likely located in an electrical room. The system coding is likely temporal.

Annunciators[edit | edit source]

There is a Mircom RAM-1032TZDS LED annunciator at the entrance, mounted in Siemens-branded cabinet.

Notification Appliances[edit | edit source]

All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Edwards 275-C111 conventional single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Edwards 6250C conventional ionization smoke detectors throughout.
Some areas, including all units, have Edwards 281C conventional 135-degree fixed-temperature/rate-of-rise heat detectors.
There are System Sensor 5601A conventional 135-degree fixed-temperature/rate-of-rise heat detectors as deficiency replacements.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all circuits.