Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Grand Professional Building: Difference between revisions

From FireAlarmPedia
(We had an overhaul!)
(Cleaned up the page and corrected some info; I couldn't find any smokes in the building, but there's likely some in the stairwells.)
 
(One intermediate revision by one other user not shown)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST iO500 <br />FACP Location: Main Entrance <br>System Type:Addressable<br /> System Line Voltage: 120VAC<br />NAC Voltage:24VFWR<br /> System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br>Date of last known Upgrade: N/A <br />Year Opened: 2012
| FACP: EST iO500 <br />FACP Location: Main Entrance Vestibule<br>System Type: Single-Stage Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage:24VFWR<br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br>Date of last known Upgrade: N/A <br />Year Opened: 2012
|}
|}
''Grand Professional Building''' is a 2-story multi-use retail and medical building in Cochrane, AB. It is located at 100 Grande Blvd. The building was built in 2012, and retains its original system.
'''Grand Professional Building''' is a 2-story multi-use retail and medical building located at 100 Grande Blvd, in Cochrane, Alberta, Canada. The building was built in 2012, and the fire alarm system is original.
 
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
 
The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST's Signature addressable protocol, and the system coding is temporal.
The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the lobby right next to the main doors. The system runs EST's Signature-series protocol; the system coding is temporal.
 
==== Notification Appliances ====
==== Notification Appliances ====
 
All notification appliances are Edwards "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).
All notification appliances are EST "Genesis" G1R-HDVM (red, wall-mount, multi-candela, no FIRE lettering) horn/strobes, located throughout and in the waiting areas of the medical offices. They are all set to 15cd.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All pull stations are EST SIGA-270 addressable single-action pull stations.  
All pull stations are EST SIGA-270 Signature-series addressable single-stage pull stations.  
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There are EST SIGA-PS addressable photoelectric smoke detectors at the top of each stairwell, mounted on EST SIGA-SB bases.
There are EST SIGA-PS addressable photoelectric smoke detectors located throughout, on SIGA-SB bases.
==== Modules ====
==== Modules ====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
==== EOLs ====
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
[[Category:Alberta]]
[[Category:Alberta]]
[[Category:Commercial]]
[[Category:Commercial]]

Latest revision as of 16:14, 28 September 2024

System Specifications
FACP: EST iO500
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage:24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: N/A
Year Opened: 2012

Grand Professional Building is a 2-story multi-use retail and medical building located at 100 Grande Blvd, in Cochrane, Alberta, Canada. The building was built in 2012, and the fire alarm system is original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST's Signature addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are Edwards "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are EST SIGA-PS addressable photoelectric smoke detectors at the top of each stairwell, mounted on EST SIGA-SB bases.

Modules[edit | edit source]

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

EOLs[edit | edit source]

There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.