The Bowness location of the fast food chain McDonald's was built sometime in the 1980s. It's located in NW Calgary. The system was installed in 2016, following a renovation.
The Bowness location of the fast food chain '''McDonald's''' was built sometime in the 1980s. It's located in NW Calgary. The fire alarm system was installed in 2016, following a major renovation.
 
NOTE: This page is severely outdated, and does not have proper details.  This page should not be used for official purposes.


== System Specifications ==
== System Specifications ==
Line 5: Line 7:
==== FACP ====
==== FACP ====


The fire alarm panel is a Simplex 4007ES. It is located in the back kitchen, which is kind of an odd placement for a panel.
The fire alarm panel is a Simplex 4007ES. It is located in the back kitchen, which is sort of an odd location for a panel.


==== Notification Appliances ====
==== Notification Appliances ====


All notification appliances consist of Simplex "TrueAlert" 4906-9127 (red, wall mount) horn/strobes. They were installed in 2016, along with the rest of the Simplex system.
The notification appliances are Simplex "TrueAlert" 4906-9127 (red, wall mount) horn/strobes. They were installed in 2016, along with the rest of the Simplex system.


=== Initiating Devices ===
=== Initiating Devices ===
Line 21: Line 23:
None noticed at this time.
None noticed at this time.


[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]

Latest revision as of 12:04, 12 October 2024

The Bowness location of the fast food chain McDonald's was built sometime in the 1980s. It's located in NW Calgary. The fire alarm system was installed in 2016, following a major renovation.

NOTE: This page is severely outdated, and does not have proper details. This page should not be used for official purposes.

System Specifications[edit | edit source]

FACP[edit | edit source]

The fire alarm panel is a Simplex 4007ES. It is located in the back kitchen, which is sort of an odd location for a panel.

Notification Appliances[edit | edit source]

The notification appliances are Simplex "TrueAlert" 4906-9127 (red, wall mount) horn/strobes. They were installed in 2016, along with the rest of the Simplex system.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations consist of Simplex 4099-9004 addressable, IDNet, single action T-bar pull stations with LED.

Automatic Detection Devices[edit | edit source]

None noticed at this time.