The '''Transit Terminal''' also known as Downtown Terminal, is a bus station in Medicine Hat. It was built in 1986, and has most of the original fire alarm system.
{| style="float:right;border:2px solid black"
 
|-
! System Specifications
|-
|
|-
| FACP: Simplex 4007ES <br>FACP Location: Unknown<br />System Type: Conventional<br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: Temporal?<br />Date of last known Upgrade: 2015 <br />Year Opened: 1986
|}
The '''Transit Terminal''' also known as Downtown Terminal, is a bus station located at 333 6 Ave, Medicine Hat. It was built in 1986, and has most of the original fire alarm system.
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel location is unknown, and has a Simplex 4007-9801 zone card installed in it. The system coding is likely temporal.


The fire alarm control panel is a Simplex 4007ES. It is confirmed a 4007ES due to an annunciator at the entrance, however the main panel is not visible. The 4007ES replaced the original Edwards 2280 in 2015. Despite the 4007ES being an addressable panel, the system is not set up in an addressable manner.
The 4007ES replaced the original Edwards 2280 in 2015.
 
===== Annunciators =====
==== Notification Appliances ====
There is a Simplex 4606-9202 LCD annunciator at the entrance.
 
====Notification Appliances====
The notification appliances consist of Edwards 439D-6AWC vibrating bells, original to the terminal.  
The notification appliances consist of Edwards 439D-6AWC vibrating bells.  
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
The pull stations consist of Edwards 270-SPO and some Edwards 274-111 pull stations.  
The pull stations consist of Edwards 270-SPO and some Edwards 274-111 pull stations. These pull stations are original to the terminal.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.
None noticed.
[[Category:Facilities]]
[[Category:Alberta]]
[[Category:Transit]]

Latest revision as of 21:13, 25 May 2024

System Specifications
FACP: Simplex 4007ES
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal?
Date of last known Upgrade: 2015
Year Opened: 1986

The Transit Terminal also known as Downtown Terminal, is a bus station located at 333 6 Ave, Medicine Hat. It was built in 1986, and has most of the original fire alarm system.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Simplex 4007ES conventional fire alarm system. The panel location is unknown, and has a Simplex 4007-9801 zone card installed in it. The system coding is likely temporal.

The 4007ES replaced the original Edwards 2280 in 2015.

Annunciators[edit | edit source]

There is a Simplex 4606-9202 LCD annunciator at the entrance.

Notification Appliances[edit | edit source]

The notification appliances consist of Edwards 439D-6AWC vibrating bells.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations consist of Edwards 270-SPO and some Edwards 274-111 pull stations.

Automatic Detection Devices[edit | edit source]

None noticed.