| FACP: Mircom Series 1000 <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous? <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2010s <br />Year Opened: 1980, 1998
| FACP: Mircom Series 1000 <br />FACP Location: Unknown <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous? <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2010s <br />Year Opened: 1980, 1998
|}
|}
'''Whistler Blackcomb''' is the largest ski resort in North America, located at 4545 Blackcomb Way, Whistler, British Columbia. It has the greatest uphill lift capacity, and is the busiest ski resort in Canada. The resort opened around 1966. This page will cover the Roundhouse Lodge; the daylodge located mid-mountain. It was originally built in 1980, renovated in 1988 and then expanded in 1998. The fire alarm system was mostly upgraded in 1998.
'''Whistler Blackcomb''' is the largest ski resort in North America, located at 4545 Blackcomb Way, Whistler, British Columbia. It has the greatest uphill lift capacity, and is the busiest ski resort in Canada. The resort opened around 1966. This page will cover the Roundhouse Lodge; the daylodge located mid-mountain. It was originally built in 1980, renovated in 1988 and then expanded in 1998. The fire alarm system was mostly upgraded in 1998.
Line 20: Line 20:
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed, a sprinkler system is present.
None noticed, a sprinkler system is present.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all circuits.
[[Category:British Columbia]]
[[Category:British Columbia]]
[[Category:Ski Resorts]]
[[Category:Ski Resorts]]

Latest revision as of 23:24, 11 October 2024

System Specifications
FACP: Mircom Series 1000
FACP Location: Unknown
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous?
Strobes Synchronized: No
Date of last known Upgrade: 2010s
Year Opened: 1980, 1998

Whistler Blackcomb is the largest ski resort in North America, located at 4545 Blackcomb Way, Whistler, British Columbia. It has the greatest uphill lift capacity, and is the busiest ski resort in Canada. The resort opened around 1966. This page will cover the Roundhouse Lodge; the daylodge located mid-mountain. It was originally built in 1980, renovated in 1988 and then expanded in 1998. The fire alarm system was mostly upgraded in 1998.

System Specifications (1998-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom Series 1000 conventional fire alarm system. The panel location is unknown. The system coding is most likely continuous.
This panel replaced an EST ESA2000.

Annunciators[edit | edit source]

There is a Mircom RAX-1032TZDS LED annunciator in a BB-1001 cabinet in the main entrance vestibule.

Notification Appliances[edit | edit source]

Most notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). Most of these were installed in 1988.
There are also some General Signal MB10-24 motor bells (10” gong).
There is a Notifier KMS-10-24A motor bell (10” gong) near the doors to the gondola loading area as a deficiency replacement.
The gondola loading area has an EST 202-5A-T remote strobe (red, wall-mount, 15cd) at the doors, due to higher ambient noise levels.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

Most pull stations are Edwards 275-C111 conventional pull stations.
The expansion has Edwards 270-SPO conventional pull stations.
There is a Notifier MPS-950B conventional pull station in the lobby as a deficiency replacement.

Automatic Detection Devices[edit | edit source]

None noticed, a sprinkler system is present.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all circuits.