Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Southland Station: Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
 
Line 6: Line 6:
|-
|-
| FACP: EST QuickStart QS1
| FACP: EST QuickStart QS1
FACP Location: Inside Locked Cabinet on Mezzanine Level<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
FACP Location: Inside Locked Cabinet on Mezzanine Level<br />System Type: Single-Stage Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  


System Coding: Temporal?<br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1981
System Coding: Temporal?<br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1981
Line 21: Line 21:
====Automatic Detection Devices====
====Automatic Detection Devices====
There are several EST SIGA-PS addressable photoelectric smoke detectors throughout the station, mounted on EST SIGA-SB bases.
There are several EST SIGA-PS addressable photoelectric smoke detectors throughout the station, mounted on EST SIGA-SB bases.
==== EOLs ====
There are Edwards EOL-P1 end-of-line resistor plates on all signal circuits.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Calgary]]
[[Category:Calgary]]
[[Category:Train Stations]]
[[Category:Train Stations]]
[[Category:Transit]]
[[Category:Transit]]

Latest revision as of 00:31, 13 October 2024

System Specifications
FACP: EST QuickStart QS1

FACP Location: Inside Locked Cabinet on Mezzanine Level
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal?
Date of last known Upgrade: Early 2010s
Year Opened: 1981

Southland Station is an LRT station in Calgary, Alberta. It serves the neighborhoods of Maple Ridge, Pump Hill, Palliser, Oakridge, and parts of Willow Park. This station shares a design with Heritage Station, and the fire alarm system is very similar. This station was also built in 1981, but the system here is not original.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel is located in a locked cabinet labeled “Fire Alarm Panel” on the mezzanine level, and was likely installed in the early 2010s. The system runs EST's Signature addressable protocol, and the system coding is most likely temporal.

Notification Appliances[edit | edit source]

Like Heritage Station, there is only one notification appliance in the whole station. The bell is a Mirtone 74328 vibrating bell (6” gong). It is located behind a metal grille, likely to prevent vandalism.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are several EST SIGA-PS addressable photoelectric smoke detectors throughout the station, mounted on EST SIGA-SB bases.

EOLs[edit | edit source]

There are Edwards EOL-P1 end-of-line resistor plates on all signal circuits.