More actions
No edit summary |
No edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
| FACP: Simplex 4010 <br />FACP Location: Side Entrance <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Date of last known Upgrade: 2006 <br />Year Opened: 1988 | | FACP: Simplex 4010 <br />FACP Location: Side Entrance <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SmartSync <br />Date of last known Upgrade: 2006 <br />Year Opened: 1988 | ||
|} | |} | ||
'''The STAND EASY''' is a restaurant located at 400 Geikie St, in Jasper, Alberta, Canada. The building was built in 1988, and the fire alarm system was upgraded in 2006. | '''The STAND EASY''' is a restaurant located at 400 Geikie St, in Jasper, Alberta, Canada. The building was built in 1988, and the fire alarm system was upgraded in 2006. | ||
Line 18: | Line 18: | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There may be Simplex “TrueAlarm” 4098-9733 addressable fixed-temperature/rate-of-rise heat detectors in the kitchen, mounted on 4098-9792 bases. | There may be Simplex “TrueAlarm” 4098-9733 addressable fixed-temperature/rate-of-rise heat detectors in the kitchen, mounted on 4098-9792 bases. | ||
==== EOLs ==== | |||
There are Simplex 2081-9040C end-of-line resistor plates on all circuits. | |||
[[Category:Alberta]] | [[Category:Alberta]] | ||
[[Category:Restaurants]] | [[Category:Restaurants]] |
Latest revision as of 16:24, 14 October 2024
System Specifications |
---|
FACP: Simplex 4010 FACP Location: Side Entrance System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SmartSync Date of last known Upgrade: 2006 Year Opened: 1988 |
The STAND EASY is a restaurant located at 400 Geikie St, in Jasper, Alberta, Canada. The building was built in 1988, and the fire alarm system was upgraded in 2006.
System Specifications (2006-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Simplex 4010 addressable fire alarm system. The panel is located in the side entrance vestibule. The system runs Simplex’s IDNet addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Simplex 4099-9001 addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
There may be Simplex “TrueAlarm” 4098-9733 addressable fixed-temperature/rate-of-rise heat detectors in the kitchen, mounted on 4098-9792 bases.
EOLs[edit | edit source]
There are Simplex 2081-9040C end-of-line resistor plates on all circuits.