Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Tillebrook Provincial Park Office: Difference between revisions

From FireAlarmPedia
No edit summary
Line 1: Line 1:
'''Tillebrook Provincial Park''' is a provincial park near Tilley, AB. There is a campground, with a park office that a fire alarm system, but is not powered up and in use.  
'''Tillebrook Provincial Park''' is a provincial park near Tilley, AB. There is a campground, with a park office that has a fire alarm system, but the system is not in use.  
 
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
 
The fire alarm control panel is a 1-zone EST FireShield. It is located at the entrance of the park office. The panel is currently not powered up, it is essentially factory new.  
The fire alarm control panel is a 1-zone EST FireShield. It is located at the entrance of the park office. The panel is currently not powered up, it still is basically new from factory.  
 
==== Notification Appliances ====
==== Notification Appliances ====
The notification appliance is an EST Genesis G1R-HDVM (red, wall, no FIRE marking) horn/strobe. It is right beside the entrance, and is currently not in use.  
The notification appliance is an EST Genesis G1R-HDVM (red, wall, no FIRE marking) horn/strobe. It is right beside the entrance, and is currently not in use.  
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
There are two pull stations, both being Edwards 270-SPOs. They are installed, but not in use.
The only pull station is an Edwards 270-SPO. It is installed, but not in use.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There is an Edwards SC10U-3 smoke detector located on the ceiling.
None noticed.
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 11:07, 11 May 2021

Tillebrook Provincial Park is a provincial park near Tilley, AB. There is a campground, with a park office that has a fire alarm system, but the system is not in use.

System Specifications

FACP

The fire alarm control panel is a 1-zone EST FireShield. It is located at the entrance of the park office. The panel is currently not powered up, it is essentially factory new.

Notification Appliances

The notification appliance is an EST Genesis G1R-HDVM (red, wall, no FIRE marking) horn/strobe. It is right beside the entrance, and is currently not in use.

Initiating Devices

Pull Stations

There are two pull stations, both being Edwards 270-SPOs. They are installed, but not in use.

Automatic Detection Devices

There is an Edwards SC10U-3 smoke detector located on the ceiling.