The Fish Creek Recreation Complex houses Cardel Rec South, The Calgary Public Library, Bishop O'Byrne High School, and the Shawnessy YMCA. The building was built in 2002, and expanded in 2012. The current system is from 2012, but almost all original devices still remain.
System Specifications
FACP
The original control panel was a Cerberus Pyrotronics MXL, which was original from 2002. It was upgraded to a Siemens Firefinder XLS in 2012, due to the expansion. It is set up in an addressable manner, with annunciators by every main entrance, and the panel is at the Cardel Ice (East) Entrance. The system is two-stage, and likely does slow march time in first stage, and code 3 in second stage.
Notification Appliances
The main notification appliances in the 2002 area are Cerberus BDC-10 (rebranded Wheelock MB-G10-24) motor bells on Wheelock RSSP-24MCW strobe plates, rebranded by Cerberus Pyrotronics. The 2012 addition has Siemens SFM24-6 motor bells on Siemens ST-MC-RETRO-R-B (rebranded Wheelock RSSP-24CMW) strobe plates.
Initiating Devices
Pull Stations
All pull stations are either Siemens or Cerberus HMS-2S.
Automatic Detection Devices
The smoke/heat detectors are likely from the fireprint lineup.