| FACP: Simplex 4007ES <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: Circa 2017 <br />Year Opened: 2007
| FACP: Simplex 4007ES <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: 2020 <br />Year Opened: 1978
|}
|}


'''Boston Pizza''' is Canada's largest chain of casual dining restaurants.  This particular restaurant is located in the Meridian neighbourhood of Northeast Calgary, and was built in 2007.  The fire alarm system is not original.
'''Boston Pizza''' is Canada's largest chain of casual dining restaurants.  This particular restaurant is located in the Meridian neighbourhood of Northeast Calgary off of Memorial Drive SE, and was built in 1978.  The fire alarm system is not original.


==System Specifications==
==System Specifications==
====FACP====
====FACP====
The restaurant is protected by a Simplex 4007ES hybrid fire alarm system.  This panel is a hybrid addressable panel, which means that it can be either addressable or conventional, depending on the cards inside the panel.  This particular panel is conventional.  It is located in the main entrance, and likely replaced either an EST FireShield or a Mircom FA-1000.
The restaurant is protected by a Simplex 4007ES hybrid fire alarm system.  This panel is a hybrid addressable panel, which means that it can be either addressable or conventional, depending on the cards inside the panel.  This particular panel is conventional.  It is located in the main entrance, and likely replaced either an EST FireShield or a Mircom FA-1000. The 4007ES was installed in August 2020, according to a permit that was issued as "Fire Alarm panel replacement at Memorial Boston Pizza."


====Notification Appliances====
====Notification Appliances====
Line 19: Line 19:
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The only pull station spotted was a Mircom MS-401 pull station, which was in the main entrance.  It is from before 2013, based on the logo.  It is unknown what the other pull stations are, or if this one is original.
The only pull station spotted was a Mircom MS-401 pull station, which was in the main entrance.  It is from before 2013, based on the logo.  It is unknown what the other pull stations are, or if this one is was from 2007.


====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.

Revision as of 17:40, 21 June 2021

System Specifications
FACP: Simplex 4007ES
System Type: Hybrid
System Line Voltage: 120VAC
NAC Voltage: 24VDC
Date of last known Upgrade: 2020
Year Opened: 1978

Boston Pizza is Canada's largest chain of casual dining restaurants. This particular restaurant is located in the Meridian neighbourhood of Northeast Calgary off of Memorial Drive SE, and was built in 1978. The fire alarm system is not original.

System Specifications

FACP

The restaurant is protected by a Simplex 4007ES hybrid fire alarm system. This panel is a hybrid addressable panel, which means that it can be either addressable or conventional, depending on the cards inside the panel. This particular panel is conventional. It is located in the main entrance, and likely replaced either an EST FireShield or a Mircom FA-1000. The 4007ES was installed in August 2020, according to a permit that was issued as "Fire Alarm panel replacement at Memorial Boston Pizza."

Notification Appliances

Most notification appliances are Edwards 439D-6AWC vibrating bells on EST "Integrity" 403-5A-R strobe plates (15 candela). In the party room, there is surprisingly a General Signal MB6-24 motor bell on an EST 403-5A-R strobe plate, because this building was built in 2007, and they stopped making General Signal branded bells in 2002.

Initiating Devices

Pull Stations

The only pull station spotted was a Mircom MS-401 pull station, which was in the main entrance. It is from before 2013, based on the logo. It is unknown what the other pull stations are, or if this one is was from 2007.

Automatic Detection Devices

None noticed.