| FACP: EST1 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: N/A <br />Year Opened: 1999
| FACP: EST1 <br /> FACP Location: Entrance Vestibule <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Conventional <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: N/A <br />Year Opened: 1999
|}
|}


'''Winners''' is a chain of department stores. This particular location is in the Shawnessy area, in SE Calgary. It was built in 1999 and it has its original fire alarm system. It is in a small plaza, but it is unknown if the other store has a fire alarm system. There was a permit issued for fire alarm repairs in July 2019, however everything still remains the same.
'''Winners''' is a chain of department stores. This particular location is in the Shawnessy area, in SE Calgary. It was built in 1999 and it has its original fire alarm system. It is in a small plaza, but it is unknown if the other store has a fire alarm system. There was a permit issued for fire alarm repairs in July 2019, however everything still remains the same.

Revision as of 11:34, 7 November 2022

System Specifications
FACP: EST1
FACP Location: Entrance Vestibule
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Conventional
Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Year Opened: 1999


Winners is a chain of department stores. This particular location is in the Shawnessy area, in SE Calgary. It was built in 1999 and it has its original fire alarm system. It is in a small plaza, but it is unknown if the other store has a fire alarm system. There was a permit issued for fire alarm repairs in July 2019, however everything still remains the same.

System Specifications

FACP

The fire alarm panel is an EST1. It is located in the second set of doors near the checkouts. The panel is original to the building.

Notification Appliances

The notification appliances consist of EST "Integrity" 757-7A-T horn/strobes. They are original to the building from 1999.

Initiating Devices

Pull Stations

The pull stations consist of Edwards 270-SPO pull stations. They are original to the store.

Automatic Detection Devices

None noticed.