Toby Creek Lodge: Difference between revisions

From FireAlarmPedia
mNo edit summary
No edit summary
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mircom FA-1000 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1979
| FACP: Mircom Series 1000  
FACP Location: An Entrance<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Temporal<br />Date of last known Upgrade: Early 2010s <br />Year Opened: 1979
|}
|}
 
'''Toby Creek Lodge''' is a 2-story condo building in Panorama Mountain Resort, BC. It was the first ever lodge to be in Panorama Mountain Resort, and was built in 1979. Only the pull stations are original.
'''Toby Creek Lodge''' is a 2-story condo building in Panorama Mountain Resort, BC. It was the first ever lodge to be in Panorama Mountain Resort, and was built in 1979. It doesn't have its original system, but has the original pull stations. It also has the general store.
 
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
 
The lodge is protected by a Mircom Series 1000 conventional fire alarm system. The panel is located in one of the entrances, and was installed in 2012-13 as the replacement for the original Edwards Custom 6500. The system coding is Temporal.
The fire alarm panel is a Mircom FA-1000, installed somewhere in 2012-2013. The panel is located in one of the entrances. It likely replaced an Edwards 6500 that was likely original.
 
==== Notification Appliances ====
==== Notification Appliances ====
 
The notification appliances are all Mircom "Select-A-Horn" FH-340R (red, wall-mount) horns. They replaced Edwards "Durabel" 6100D vibrating bells, as some horns have a round outline behind them.  
The notification appliances are Mircom FH-340R horns. They replaced Edwards Adaptabels/Durabels in 2012-2013, because some horns have a round outline behind them.  
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All but one pull stations are the original Edwards 270-SPO conventional pull stations. (classic shield, no FIRE ALARM). By the doors to the first floor in the right stairwell, there is a Mircom MS-401, installed as a deficiency replacement.
The pull stations are all original, they are 2nd generation Edwards 270-SPO (classic shield logo, no FIRE ALARM at top). By the doors to the first floor in the right stairwell, there is a Mircom MS-401 which replaced an original Edwards pull station around the early 2010s.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There are Mircom 2W-B "i3" photoelectric smoke detectors in the hallways of the lodge.
There are Mircom 2W-B "i3" photoelectric smoke detectors in the hallways of the lodge. They were installed when the FA-1000 was.

Revision as of 20:48, 17 November 2022

System Specifications
FACP: Mircom Series 1000

FACP Location: An Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Temporal
Date of last known Upgrade: Early 2010s
Year Opened: 1979

Toby Creek Lodge is a 2-story condo building in Panorama Mountain Resort, BC. It was the first ever lodge to be in Panorama Mountain Resort, and was built in 1979. Only the pull stations are original.

System Specifications

FACP

The lodge is protected by a Mircom Series 1000 conventional fire alarm system. The panel is located in one of the entrances, and was installed in 2012-13 as the replacement for the original Edwards Custom 6500. The system coding is Temporal.

Notification Appliances

The notification appliances are all Mircom "Select-A-Horn" FH-340R (red, wall-mount) horns. They replaced Edwards "Durabel" 6100D vibrating bells, as some horns have a round outline behind them.

Initiating Devices

Pull Stations

All but one pull stations are the original Edwards 270-SPO conventional pull stations. (classic shield, no FIRE ALARM). By the doors to the first floor in the right stairwell, there is a Mircom MS-401, installed as a deficiency replacement.

Automatic Detection Devices

There are Mircom 2W-B "i3" photoelectric smoke detectors in the hallways of the lodge.