==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located at the main entrance, and was installed in | The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located at the main entrance, and was installed in 2018. When in alarm, the system likely does code 3. The permit issued for this fire alarm system was "Fire Alarm Control Panel replacement c/w horn strobes". | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Line 23: | Line 23: | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
None noticed. | None noticed. | ||
==Former System Specifications== | ==Former System Specifications== |
Revision as of 16:45, 28 June 2021
System Specifications |
---|
FACP: Mircom FX-2000 System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR Date of last known Upgrade: 2020 Year Opened: 1998 |
Sobeys is a chain of grocery stores in Canada. This particular store is located in the McKenzie Towne neighbourhood of Southeast Calgary. This location was built in 1998, but the system has been replaced twice since then. The current system was installed following the 2020 renovation.
NOTE: Page is unfinished. Page will be finished soon, so check back later.
System Specifications
FACP
The store is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located at the main entrance, and was installed in 2018. When in alarm, the system likely does code 3. The permit issued for this fire alarm system was "Fire Alarm Control Panel replacement c/w horn strobes".
Notification Appliances
All notification appliances are Mircom FHS-400-RR LED horn/strobes (red, wall-mount). The horn/strobes mounted on the ceiling have the original lettering taped over with ceiling-oriented lettering on top. It is unknown why they didn't install ceiling-mount versions.
Initiating Devices
Pull Stations
All pull stations are Mircom MS-401AP "Advanced Protocol" addressable single-action pull stations.
Automatic Detection Devices
None noticed.
Former System Specifications
System Specifications |
---|
FACP: Mircom FX-350 System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR Date of last known Upgrade: N/A Year Decommissioned: 2020 |
FACP
The store was protected by a Mircom FX-350 addressable fire alarm system. It was installed in 2016 and decommissioned in 2020, so it wasn't in service for long. The panel was located in the front entrance. The system likely did code 3 in alarm.
Notification Appliances
All notification appliances were Mircom "Select-A-Horn" FH-340R horns (red, wall-mount).
Initiating Devices
Pull Stations
All pull stations were Mircom MS-401AP "Advanced Protocol" addressable single-action pull stations.
Automatic Detection Devices
None noticed.