System Type: Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br />Date of last known Upgrade: 2016<br />Year Opened: 1985
System Type: Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br />Date of last known Upgrade: 2016<br />Year Opened: 1985
|}
|}
== System Specifications ==
== System Specifications ==
==== FACP ====
==== FACP ====
 
The building is protected by an EST3 addressable fire alarm system. The panel is located at the main entrance.  The system runs EST's Signature-series addressable protocol, and does code 3 in alarm.
The fire alarm panel is an EST3, installed in 2016. It replaced a Siemens MXL system from 2003. This system, unlike the MXL, is not two-stage. The panel is at the front entrance, and has had two supervisories in July 2019.
 
==== Notification Appliances ====
==== Notification Appliances ====
 
Most notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, set to 15cd), mounted on EST G1RT-FIRE trim plates. The Cretaceous Gardens have EST "Genesis" WG4RF-HVMC weatherproof horn/strobes (red, wall-mount).
The notification appliances seen throughout the museum are EST "Genesis" G1R-HDVM (red, wall, no FIRE) horn/strobes on G1RT-FIRE (FIRE lettering) trim plates. They replaced Siemens U-MMT-MCS-W-B horn/strobes. In the "Cretaceous Gardens", there are EST WG4RN-HVMC (red, no FIRE) horn/strobes. For outdoor notification, there is an EST CS405-7A-T "Integrity" weatherproof strobe. There is also an Edwards 340D Adaptabel from 1985 under it, but it hasn't been in use for a while. It was part of the original system.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.
All pull stations are EST SIGC-270B (bilingual). They are in the place of the original pull stations.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the building.
There are EST SIGA2-PS smoke detectors seen throughout.
 
== Former System Specifications ==
== Former System Specifications ==
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
Line 38: Line 27:
|}
|}
==== FACP ====
==== FACP ====
 
The building was protected by a Siemens MXL addressable fire alarm system. The panel was located near the main entrance.  The system was two-stage, and did 20BPM in first stage, followed by code 3 in general alarm.
The system was a Siemens MXL from 2003. It was two-stage, and was replaced in 2016 due to an expansion.
 
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances on the MXL were Siemens U-MMT-MCS-W-B multi tone horn/strobes. They were replaced in 2016 with Genesis horn/strobes.
All notification appliances on the MXL were Siemens U-MMT-MCS-W-B multi tone horn/strobes. They were replaced in 2016 with Genesis horn/strobes.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations were Siemens HMS-2S addressable two-stage pull stations.
The pull stations were Siemens HMS-2S addressable two-stage pull stations.
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 14:37, 11 March 2022

Royal Tyrrell Museum is a paleontology and dinosaur museum in Drumheller. It is also Canada's only museum that is only for prehistoric life. The museum is also a big tourist attraction for Alberta. It was built in 1985, but has had its current fire alarm system since 2016 after an expansion.

System Specifications
FACP: EST3

System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
Date of last known Upgrade: 2016
Year Opened: 1985

System Specifications

FACP

The building is protected by an EST3 addressable fire alarm system. The panel is located at the main entrance. The system runs EST's Signature-series addressable protocol, and does code 3 in alarm.

Notification Appliances

Most notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, set to 15cd), mounted on EST G1RT-FIRE trim plates. The Cretaceous Gardens have EST "Genesis" WG4RF-HVMC weatherproof horn/strobes (red, wall-mount).

Initiating Devices

Pull Stations

All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.

Automatic Detection Devices

There are EST SIGA2-PS addressable photoelectric smoke detectors throughout the building.

Former System Specifications

System Specifications
FACP: Siemens MXL
System Type: Addressable (Two-Stage)
System Line Voltage: 120VAC
NAC Voltage: 24VDC
Date of last known Upgrade: N/A
Year Decommissioned: 2016

FACP

The building was protected by a Siemens MXL addressable fire alarm system. The panel was located near the main entrance. The system was two-stage, and did 20BPM in first stage, followed by code 3 in general alarm.

Notification Appliances

All notification appliances on the MXL were Siemens U-MMT-MCS-W-B multi tone horn/strobes. They were replaced in 2016 with Genesis horn/strobes.

Initiating Devices

Pull Stations

The pull stations were Siemens HMS-2S addressable two-stage pull stations.