'''Lake Louise Visitor Centre''' is the visitor centre in Lake Louise, AB. It was built around the 1990s, and recently went under a renovation from October 2018 to August 2019. The current fire alarm system was installed during the renovation. | '''Lake Louise Visitor Centre''' is the visitor centre in Lake Louise, AB. It was built around the 1990s, and recently went under a renovation from October 2018 to August 2019. The current fire alarm system was installed during the renovation. | ||
== System Specifications == | == System Specifications (2019-present) == | ||
==== FACP ==== | ==== FACP ==== | ||
Line 40: | Line 40: | ||
|} | |} | ||
== Former System Specifications == | == Former System Specifications (1990s-2018) == | ||
==== FACP ==== | ==== FACP ==== |
Revision as of 12:28, 8 February 2022
System Specifications |
---|
FACP: Notifier NFS-320C? System Type: Addressable (Hybrid Manner) System Line Voltage: 120VAC NAC Voltage: 24VDC Date of last known Upgrade: 2018-2019 Year Opened: 1990s |
Lake Louise Visitor Centre is the visitor centre in Lake Louise, AB. It was built around the 1990s, and recently went under a renovation from October 2018 to August 2019. The current fire alarm system was installed during the renovation.
System Specifications (2019-present)
FACP
The building is likely protected by a Notifier NFS-320C fire alarm system. The panel is not visible, but is assumed due to the size of the building and the year it was renovated. It was installed during the renovation. It replaced an Edwards system of some sort, which could have been original.
Notification Appliances
The notification appliances are System Sensor "L-Series" P2WLA (white, wall mount, 2-wire, English/French lettering) horn/strobes, set to 15cd and 30cd depending on location. They were probably chosen to blend in with the walls, and were installed during the renovations. However, in the men's washroom, remains a now-disconnected Edwards 439D-6AWC vibrating bell, left over from the previous system.
Initiating Devices
Pull Stations
The pull stations are Notifier MPS-950B which were installed during the renovation.
Automatic Detection Devices
None noticed.
Former System Specifications |
---|
FACP: Presumably EST2 or similar System Type: Conventional/Hybrid System Line Voltage: 120VAC NAC Voltage: 24VDC or 24VFWR, depending on what was there Date of last known Upgrade: N/A Year Decomissioned: 2018 |
Former System Specifications (1990s-2018)
FACP
The building was previously protected by some Edwards or EST fire alarm system. It is unknown what the panel was as this is based off of photos.
Notification Appliances
The main notification appliances were Edwards 439D-10AWC vibrating bells. In the washrooms, there were (and still are, but disconnected) Edwards 439D-6AWC vibrating bells.
Initiating Devices
Pull Stations
The pull stations were Edwards 270-SPO pull stations.
Automatic Detection Devices
Not Available.