More actions
Line 117: | Line 117: | ||
!Manufacturing Date | !Manufacturing Date | ||
!Notes | !Notes | ||
!Origin | |||
|- | |- | ||
| Mircom MS-401 | | Mircom MS-401 | ||
Line 124: | Line 125: | ||
|Late 2010s (one 2017) | |Late 2010s (one 2017) | ||
|First alarm I ever got. | |First alarm I ever got. | ||
|AMRE Supply (overpriced! Just go to Mircom themselves.) | |||
|- | |- | ||
|Edwards 270-GAO | |Edwards 270-GAO | ||
Line 131: | Line 133: | ||
|1977 | |1977 | ||
|Came out of the Calgary General Hospital | |Came out of the Calgary General Hospital | ||
| | |||
|- | |- | ||
|Simplex 4251-30 | |Simplex 4251-30 | ||
Line 137: | Line 140: | ||
|Dual-action (break glass) conventional T-bar pull station | |Dual-action (break glass) conventional T-bar pull station | ||
| 11th week of 1979 | | 11th week of 1979 | ||
| | |Currently in possession of [[User:Yycsfirealarmnimrod|Yycsfirealarmnimrod]], and in use on [[YYCsFireAlarmNimrod's Basement]]. | ||
|Kijiji | |||
|- | |- | ||
|Edwards 275-C111 | |Edwards 275-C111 | ||
Line 145: | Line 149: | ||
|late 1980s-early 1990s | |late 1980s-early 1990s | ||
| | | | ||
|Canadian Alarms | |||
|- | |- | ||
|Mircom MS-401AD | |Mircom MS-401AD | ||
Line 152: | Line 157: | ||
|2008 | |2008 | ||
| | | | ||
|Canadian Alarms | |||
|- | |- | ||
| Edwards 270-SPO | | Edwards 270-SPO | ||
Line 160: | Line 166: | ||
2009 (1) | 2009 (1) | ||
| | | | ||
|Kijiji (1960s), [[User:Yycsfirealarmnimrod|Yycsfirealarmnimrod]] (2009) | |||
|- | |- | ||
|Edwards 270-SPOW | |Edwards 270-SPOW | ||
Line 167: | Line 174: | ||
|2011 | |2011 | ||
| | | | ||
|Canadian Alarms | |||
|- | |- | ||
|Simplex 4099-9004 | |Simplex 4099-9004 | ||
| | | | ||
|1 | |1 | ||
|Addressable single-stage T-bar pull station with LED | |Addressable IDNET single-stage T-bar pull station with LED | ||
|2018 | |2018 | ||
| | | | ||
|Canadian Alarms | |||
|- | |- | ||
|Pyrotronics MS- | |Pyrotronics MS-51B | ||
| | | | ||
|1 | |1 | ||
Line 181: | Line 190: | ||
|1980s | |1980s | ||
|Branded "Pyr-A-Larm" | |Branded "Pyr-A-Larm" | ||
|El Chupacabra | |||
|- | |- | ||
|Fire-Lite BG-12 | |Fire-Lite BG-12 | ||
Line 188: | Line 198: | ||
|2001 | |2001 | ||
| | | | ||
|El Chupacabra | |||
|- | |- | ||
|Mirtone 73303 | |Mirtone 73303 | ||
Line 195: | Line 206: | ||
|1986 | |1986 | ||
| | | | ||
|Canadian Alarms, [[User:Yycsfirealarmnimrod|Yycsfirealarmnimrod]] | |||
|} | |} | ||
===Automatic Detection Devices=== | ===Automatic Detection Devices=== | ||
Line 205: | Line 217: | ||
!Manufacturing Date | !Manufacturing Date | ||
!Notes | !Notes | ||
!Origin | |||
|- | |- | ||
|Edwards 281C | |Edwards 281C | ||
Line 212: | Line 225: | ||
|1994 | |1994 | ||
| | | | ||
|Canadian Alarms | |||
|- | |- | ||
|Edwards 281B-PL | |Edwards 281B-PL | ||
Line 219: | Line 233: | ||
|2010 | |2010 | ||
|Came with base | |Came with base | ||
|[[User:Yycsfirealarmnimrod|Yycsfirealarmnimrod]] | |||
|- | |- | ||
|Mirtone 73340 | |Mirtone 73340 | ||
Line 226: | Line 241: | ||
|1998 | |1998 | ||
| | | | ||
|[[Phuntington|Paul Huntington]] | |||
|- | |- | ||
|Edwards C2M-PD | |Edwards C2M-PD | ||
Line 233: | Line 249: | ||
|2010 | |2010 | ||
| | | | ||
|[[Phuntington|Paul Huntington]] | |||
|- | |- | ||
|System Sensor 2400A | |System Sensor 2400A | ||
Line 240: | Line 257: | ||
|Unknown (1990s-2000s) | |Unknown (1990s-2000s) | ||
| | | | ||
|Thomas Barnable | |||
|} | |} |
Revision as of 11:46, 9 September 2021
I have been collecting fire alarms since 2017, and I have a good number of devices.
FACP (Panels)
Model | Image | Type | Zone/Point Capacity | NACs | Coding Options | Power Supply | NAC Voltage | System Line Voltage | Synchronization Support | Manufacturing Date | Origin |
---|---|---|---|---|---|---|---|---|---|---|---|
Fire-Lite MS-4 | Conventional | 4 zones | 2 | Code-3, continuous | 3A (expandable to 6A) | 24VFWR | 120VAC | System Sensor, Wheelock, Gentex | December 18, 2015 | Yycsfirealarmnimrod |
Notification Appliances
Model Number | Images | Quantity | Type | Voltage | Strobe Intensity | Loudness | Manufacturing Date | Notes |
---|---|---|---|---|---|---|---|---|
Edwards 333D | 1 | 6" Single-Stroke bell | 24VDC | N/A | 92 dB | 1976 | From the "Adaptabel" line.
Came out of the Calgary General Hospital. Has been modified to allow easier wiring to panels. | |
Unbranded Alarm Bell
from Amazon |
1 | 6" motor bell | 24VDC | N/A | 95 dB | 2017 | Also known as the "FakeBell"
Works on 9VDC | |
EST 757-5A-T | 1 | Temporal horn/strobe | 20-24VDC | 15cd | 98/102 dB | 1997 | From the "Integrity" lineup
Came out of a Walmart in Ontario. | |
Wheelock WM3T-24 | 1 | Weatherproof strobe | 18-31VDC | 117cd (78cd at -35C) | N/A | 1993 | ||
Mirtone 74306 | 1 | 10" motor bell | 24VDC | N/A | 95 dB? | Late 1980s-early 1990s | ||
Edwards/EST (GE) 682-1C | 1 | Mini-horn | 20-24VDC | N/A | 91 dB? | 2008 |
Pull Stations
Model Number | Images | Quantity | Type | Manufacturing Date | Notes | Origin |
---|---|---|---|---|---|---|
Mircom MS-401 | 2 | Conventional, single stage pull station | Late 2010s (one 2017) | First alarm I ever got. | AMRE Supply (overpriced! Just go to Mircom themselves.) | |
Edwards 270-GAO | 2 | Two-stage conventional pull station | 1977 | Came out of the Calgary General Hospital | ||
Simplex 4251-30 | 1 | Dual-action (break glass) conventional T-bar pull station | 11th week of 1979 | Currently in possession of Yycsfirealarmnimrod, and in use on YYCsFireAlarmNimrod's Basement. | Kijiji | |
Edwards 275-C111 | 1 | Metal conventional pull station | late 1980s-early 1990s | Canadian Alarms | ||
Mircom MS-401AD | 1 | Addressable single-stage pull station | 2008 | Canadian Alarms | ||
Edwards 270-SPO | 2 | Conventional single-stage pull station | 1960s (1)
2009 (1) |
Kijiji (1960s), Yycsfirealarmnimrod (2009) | ||
Edwards 270-SPOW | 1 | Conventional single-stage pull station with Wire Terminals | 2011 | Canadian Alarms | ||
Simplex 4099-9004 | 1 | Addressable IDNET single-stage T-bar pull station with LED | 2018 | Canadian Alarms | ||
Pyrotronics MS-51B | 1 | Conventional, bilingual single action pull station | 1980s | Branded "Pyr-A-Larm" | El Chupacabra | |
Fire-Lite BG-12 | 1 | Conventional dual-action pull station | 2001 | El Chupacabra | ||
Mirtone 73303 | 2 | Conventional pull station | 1986 | Canadian Alarms, Yycsfirealarmnimrod |
Automatic Detection Devices
Model Number | Images | Quantity | Type | Manufacturing Date | Notes | Origin |
---|---|---|---|---|---|---|
Edwards 281C | 1 | Fixed Temperature/Rate-of-Rise Heat Detector | 1994 | Canadian Alarms | ||
Edwards 281B-PL | 1 | Fixed Temperature/Rate-of-Rise Heat Detector | 2010 | Came with base | Yycsfirealarmnimrod | |
Mirtone 73340 | 1 | Fixed Temperature/Rate-of-Rise Heat Detector | 1998 | Paul Huntington | ||
Edwards C2M-PD | 1 | 2-wire, self-diagnostic photoelectric smoke detector | 2010 | Paul Huntington | ||
System Sensor 2400A | 1 | direct-wire, photoelectric smoke detector | Unknown (1990s-2000s) | Thomas Barnable |