''''Anchor Inn and Suites'''' is a hotel located in Twillingate, Newfoundland.  It also contains Georgie's Restaurant.  The building was built in the 1980s or 1990s, and has the original fire alarm system.
{| style="float:right;border:2px solid black"
|-
! System Specifications
|-
|
|-
| FACP: EST 6616 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Year Opened: Early 1990s
|}
 
'''Anchor Inn and Suites''' is a hotel located in Twillingate, Newfoundland.  It also contains Georgie's Restaurant.  The building was built in the early 1990s, and has the original fire alarm system.


==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by an Edwards 6616 16-zone conventional fire alarm system.  The panel is located across from the front desk.  This panel has suffered a main board failure, and is stuck in alarm.  Therefore, the system is inoperable, and should be replaced immediately.  The system likely does continuous in alarm.
The building is protected by an EST 6616 16-zone conventional fire alarm system.  The panel is located across from the front desk.  This panel has suffered a main board failure, and is stuck in alarm.  Therefore, the system is inoperable, and should be replaced immediately.  The system likely does continuous in alarm.


====Notification Appliances====
====Notification Appliances====
Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong).  There are also Edwards 403-5A-R remote strobes (15 cd)throughout the hotel.  One of these strobes is stuffed into a ceiling tile, which obstructs the field of view for it.
Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong).  There are also EST "Integrity" 202-5A-T remote strobes(15cd) throughout the hotel.  One of these strobes is stuffed into a ceiling tile, which obstructs the field of view for it.


===Initiating Devices===
===Initiating Devices===
Line 16: Line 25:


==Bonus Information==
==Bonus Information==
-The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki.
*The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki.
-This building has the most fire alarm issues ever spotted by the staff of this wiki.
*This building has the most fire alarm issues ever spotted by the staff of this wiki.

Revision as of 11:36, 8 November 2021

System Specifications
FACP: EST 6616
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
Date of last known Upgrade: N/A
Year Opened: Early 1990s

Anchor Inn and Suites is a hotel located in Twillingate, Newfoundland. It also contains Georgie's Restaurant. The building was built in the early 1990s, and has the original fire alarm system.

System Specifications

FACP

The building is protected by an EST 6616 16-zone conventional fire alarm system. The panel is located across from the front desk. This panel has suffered a main board failure, and is stuck in alarm. Therefore, the system is inoperable, and should be replaced immediately. The system likely does continuous in alarm.

Notification Appliances

Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong). There are also EST "Integrity" 202-5A-T remote strobes(15cd) throughout the hotel. One of these strobes is stuffed into a ceiling tile, which obstructs the field of view for it.

Initiating Devices

Pull Stations

All pull stations are Edwards 270-SPO conventional single-action "teardrop" pull stations.

Automatic Detection Devices

There are Edwards 6249C 4-wire ionization smoke detectors throughout the hotel.

Bonus Information

  • The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki.
  • This building has the most fire alarm issues ever spotted by the staff of this wiki.