| FACP: EST 6616 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Year Opened: Early 1990s | | FACP: EST 6616 | ||
FACP Location: Main Lobby<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR | |||
System Coding: Continuous<br />Date of last known Upgrade: N/A <br />Year Opened: Early 1990s | |||
|} | |} | ||
'''Anchor Inn and Suites''' is a hotel located in Twillingate, Newfoundland. It also contains Georgie's Restaurant. The building was built in the early 1990s, and has the original fire alarm system. | |||
'''Anchor Inn and Suites''' is a hotel located in Twillingate, Newfoundland. | |||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The building is protected by an EST 6616 16-zone conventional fire alarm system. | The building is protected by an EST 6616 16-zone conventional fire alarm system. The panel is located across from the front desk. This panel has suffered a main board failure, and is stuck in alarm. Therefore, the system is inoperable, and should be replaced immediately. The system coding is likely continuous. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong). | Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong). There are also EST "Integrity" 202-5A-T remote strobes (red, wall-mount, 15cd) throughout the hotel. One strobe is resting on a cutout of a ceiling tile, and therefore does not have proper coverage. | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Edwards 270-SPO conventional single-action | All pull stations are Edwards 270-SPO conventional single-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Edwards 6249C 4-wire ionization smoke detectors throughout the hotel. | There are Edwards 6249C conventional 4-wire ionization smoke detectors throughout the hotel. | ||
==Bonus Information== | ==Bonus Information== | ||
*The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki. | *The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki. | ||
*This building has the most fire alarm issues ever spotted by the staff of this wiki. | *This building has the most fire alarm issues ever spotted by the staff of this wiki. |
Revision as of 10:29, 15 November 2022
System Specifications |
---|
FACP: EST 6616
FACP Location: Main Lobby System Coding: Continuous |
Anchor Inn and Suites is a hotel located in Twillingate, Newfoundland. It also contains Georgie's Restaurant. The building was built in the early 1990s, and has the original fire alarm system.
System Specifications
FACP
The building is protected by an EST 6616 16-zone conventional fire alarm system. The panel is located across from the front desk. This panel has suffered a main board failure, and is stuck in alarm. Therefore, the system is inoperable, and should be replaced immediately. The system coding is likely continuous.
Notification Appliances
Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong). There are also EST "Integrity" 202-5A-T remote strobes (red, wall-mount, 15cd) throughout the hotel. One strobe is resting on a cutout of a ceiling tile, and therefore does not have proper coverage.
Initiating Devices
Pull Stations
All pull stations are Edwards 270-SPO conventional single-action pull stations.
Automatic Detection Devices
There are Edwards 6249C conventional 4-wire ionization smoke detectors throughout the hotel.
Bonus Information
- The restaurant in this hotel, Georgie's, is very good, and is highly recommended by the staff of this Wiki.
- This building has the most fire alarm issues ever spotted by the staff of this wiki.