Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

FreshCo (Okotoks): Difference between revisions

From FireAlarmPedia
(These aren't 73303s. They're 73353s, which are even rarer. I know this because I have one.)
(overhaul. Mirtone!)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Mirtone 7532 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: N/A <br />Year Opened: 1998
| FACP: Mirtone 7532  
FACP Location: Main Entrance<br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR  
 
System Coding: Continuous
 
Strobes Synchronized: Yes<br />Date of last known Upgrade: N/A <br />Year Opened: 1998
|}
|}
'''Safeway''' is a grocery store chain in North America. This particular location is located in Okotoks, Alberta, and was built in 1998. The fire alarm system is original.
'''Safeway''' is a grocery store chain in North America. This particular location is located at 610 Big Rock Lane in Okotoks, Alberta, and was built in 1998. The fire alarm system is original.
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The fire alarm panel is an extremely rare Mirtone 7532 (rebranded Edwards 6632), which is original. The panel is located in the main entrance.
The store is protected by a Mirtone 7532 conventional fire alarm system. The panel is located in the main entrance. The system coding is continuous.
====Notification Appliances====
====Notification Appliances====
The notification appliances are the original General Signal MB10-24 motor bells on EST "Integrity" 403-5A-R strobe plates.
The notification appliances are the General Signal MB10-24 motor bells (10" gong) on EST "Integrity" 403-5A-R (15cd) strobe plates.
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The pull stations are Mirtone 73353 conventional single-action pull stations, which are undoubtedly original. These are also extremely rare.
The pull stations are Mirtone 73353 conventional single-action pull stations, which are undoubtedly original. These are also extremely rare.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed, possibly waterflow protection.

Revision as of 00:07, 22 November 2022

System Specifications
FACP: Mirtone 7532

FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR

System Coding: Continuous

Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Year Opened: 1998

Safeway is a grocery store chain in North America. This particular location is located at 610 Big Rock Lane in Okotoks, Alberta, and was built in 1998. The fire alarm system is original.

System Specifications

FACP

The store is protected by a Mirtone 7532 conventional fire alarm system. The panel is located in the main entrance. The system coding is continuous.

Notification Appliances

The notification appliances are the General Signal MB10-24 motor bells (10" gong) on EST "Integrity" 403-5A-R (15cd) strobe plates.

Initiating Devices

Pull Stations

The pull stations are Mirtone 73353 conventional single-action pull stations, which are undoubtedly original. These are also extremely rare.

Automatic Detection Devices

None noticed, possibly waterflow protection.