More actions
(Created page with "'''''Jack Setters Arena''''' is an indoor hockey arena owned by the Millican - Ogden Community Association. The arena was built in 1972, ==System Specifications== ====FACP====...") |
(Great start, theo! Please try not to use "I" as all of our staff edit this page, so if a specific user is mentioned, it will be in a username. Also try not to use FIVE apostrophes, three will do just fine. 439D-10AWCs are the ones in Canada. Otherwise, good start!) |
||
Line 1: | Line 1: | ||
'''Jack Setters Arena''' is an indoor hockey arena owned by the Millican - Ogden Community Association. The arena was built in 1972. | |||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The facility is protected by a Mircom FA-300 Series Conventional fire alarm control panel. The panel is located in the main entrance. When in alarm the system most likely does steady code. | The facility is protected by a Mircom FA-300 Series Conventional fire alarm control panel. The panel is located in the main entrance. When in alarm the system most likely does steady code/continuous. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances consist of | Most notification appliances consist of three Edwards 439D-10AWC (10 Inch) vibrating bells, located in the lobby, rink area, and Zamboni room | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
There are 3 pull stations in this building, two of which are Edwards | There are 3 pull stations in this building, two of which are Edwards 270-SPO conventional pull stations and one Notifier MPS-950B conventional pull station as a replacement. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
None noticed. |
Revision as of 20:10, 21 February 2022
Jack Setters Arena is an indoor hockey arena owned by the Millican - Ogden Community Association. The arena was built in 1972.
System Specifications
FACP
The facility is protected by a Mircom FA-300 Series Conventional fire alarm control panel. The panel is located in the main entrance. When in alarm the system most likely does steady code/continuous.
Notification Appliances
Most notification appliances consist of three Edwards 439D-10AWC (10 Inch) vibrating bells, located in the lobby, rink area, and Zamboni room
Initiating Devices
Pull Stations
There are 3 pull stations in this building, two of which are Edwards 270-SPO conventional pull stations and one Notifier MPS-950B conventional pull station as a replacement.
Automatic Detection Devices
None noticed.