Cambridge Red Deer Hotel & Conference Centre: Difference between revisions

From FireAlarmPedia
mNo edit summary
(Tweaked the page to fit the modern format.)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: EST3 <br />System Type:Addressable (Two-stage) <br /> System Line Voltage: 120VAC<br />NAC Voltage:70.7VRMS (audible) <br> 24VDC (visual) <br />Date of last known Upgrade: 2013 <br />Year Opened: 1956
| FACP: EST3  
|}
FACP Location: Behind Front Desk<br />System Type:Addressable (Two-stage) <br /> System Line Voltage: 120VAC<br />NAC Voltage:70.7VRMS (audible) <br> 24VDC (visual)  


'''Cambridge Red Deer Hotel & Conference Centre''' is a hotel in Red Deer, Alberta.  It has a large conference centre, as well as a pool, and many other amenities.  It opened in 1956, and was renovated in 2007.  The fire alarm system was upgraded in 2013.  This page will cover both the current and previous fire alarm systems.
System Coding: Unknown


Strobes Synchronized: Yes, EST<br />Date of last known Upgrade: 2013 <br />Year Opened: 1956
|}
'''Cambridge Red Deer Hotel & Conference Centre''' is a hotel in Red Deer, Alberta. It has a large conference centre, as well as a pool, and many other amenities. It opened in 1956, and was renovated in 2007. The fire alarm system was upgraded in 2013. This page will cover both the current and previous fire alarm systems.
==System Specifications (2013-present)==
==System Specifications (2013-present)==
====FACP====
====FACP====
The building is protected by an EST3 addressable fire alarm system. The panel is located behind the front desk. The system runs EST’s Signature-series addressable protocol, is voice evac, and is two stage.  
The building is protected by an Edwards EST3 addressable fire alarm system. The panel is located behind the front desk. The system runs EST’s Signature-series addressable protocol, and is equipped with voice evacuation.  The system is configured for two-stage operation, however the messages and/or tones are unknown at this time.  
 
====Notification Appliances====
====Notification Appliances====
The notification appliances vary throughout the hotel. The hallways, lobby area, conference centre, and most other common areas have EST 757-5A-SS70 “Enhanced Integrity” speaker/strobes (70V, red, wall-mount). The pool area has System Sensor “SpectrAlert Advance” SPRKA speakers (70V, red, wall-mount) with EST CS405-7A-T weatherproof remote strobes beside or underneath them.
The notification appliances vary throughout the hotel. The hallways, lobby area, conference centre, and most other common areas have EST 757-5A-SS70 “Enhanced Integrity” speaker/strobes (70V, red, wall-mount). The pool area has System Sensor “SpectrAlert Advance” SPRKA speakers (70V, red, wall-mount) with EST CS405-7A-T weatherproof remote strobes (red, wall-mount, 15/75cd) beside or underneath them.  
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-270P Signature-series addressable 2-stage single-action pull stations.
All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
There are EST SIGA-PS Signature-series addressable photoelectric smoke detectors throughout the facility. The detectors in the rooms are mounted on EST SIGA-AB4G sounder bases.
There are EST SIGA-PS Signature-series addressable photoelectric smoke detectors throughout the facility. The detectors in the rooms are mounted on EST SIGA-AB4G sounder bases, and are mounted on EST SIGA-SB bases in common areas.




Line 35: Line 35:
|}
|}
====FACP====
====FACP====
The fire alarm panel driving the previous system is unknown. There is no evidence as to what the old panel could have been.
The fire alarm panel driving the previous system is unknown. There is no evidence as to what the old panel could have been.
 
====Notification Appliances====
====Notification Appliances====
Most areas of the hotel had Edwards 439D-6AWC vibrating bells (6” gong) on EST "Integrity" 403-5A-R strobe plates (15cd). The conference centre had Edwards 439D-10AWC vibrating bells (10” gong), also on 403-5A-R strobe plates (15cd).
Most areas of the hotel had Edwards 439D-6AWC vibrating bells (6” gong) on EST "Integrity" 403-5A-R strobe plates (15cd). The conference centre had Edwards 439D-10AWC vibrating bells (10” gong), also on 403-5A-R strobe plates (15cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The pull stations were a mix of Edwards 275-C111 conventional single-action pull stations and Mirtone 73303 conventional single-action pull stations.
The pull stations were a mix of Edwards 275-C111 conventional single-action pull stations and Mirtone 73303 conventional single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
Unknown.
Unknown.

Revision as of 13:10, 18 November 2022

System Specifications
FACP: EST3

FACP Location: Behind Front Desk
System Type:Addressable (Two-stage)
System Line Voltage: 120VAC
NAC Voltage:70.7VRMS (audible)
24VDC (visual)

System Coding: Unknown

Strobes Synchronized: Yes, EST
Date of last known Upgrade: 2013
Year Opened: 1956

Cambridge Red Deer Hotel & Conference Centre is a hotel in Red Deer, Alberta. It has a large conference centre, as well as a pool, and many other amenities. It opened in 1956, and was renovated in 2007. The fire alarm system was upgraded in 2013. This page will cover both the current and previous fire alarm systems.

System Specifications (2013-present)

FACP

The building is protected by an Edwards EST3 addressable fire alarm system. The panel is located behind the front desk. The system runs EST’s Signature-series addressable protocol, and is equipped with voice evacuation. The system is configured for two-stage operation, however the messages and/or tones are unknown at this time.

Notification Appliances

The notification appliances vary throughout the hotel. The hallways, lobby area, conference centre, and most other common areas have EST 757-5A-SS70 “Enhanced Integrity” speaker/strobes (70V, red, wall-mount). The pool area has System Sensor “SpectrAlert Advance” SPRKA speakers (70V, red, wall-mount) with EST CS405-7A-T weatherproof remote strobes (red, wall-mount, 15/75cd) beside or underneath them.

Initiating Devices

Pull Stations

All pull stations are EST SIGA-270P addressable two-stage single-action pull stations.

Automatic Detection Devices

There are EST SIGA-PS Signature-series addressable photoelectric smoke detectors throughout the facility. The detectors in the rooms are mounted on EST SIGA-AB4G sounder bases, and are mounted on EST SIGA-SB bases in common areas.


System Specifications (Previous System) (Early 1990s-2013)

System Specifications
FACP: Unknown
System Type:Conventional/Hybrid
System Line Voltage: 120VAC
NAC Voltage:24VDC
Date of last known Upgrade: Unknown
Year Decommissioned: 2013

FACP

The fire alarm panel driving the previous system is unknown. There is no evidence as to what the old panel could have been.

Notification Appliances

Most areas of the hotel had Edwards 439D-6AWC vibrating bells (6” gong) on EST "Integrity" 403-5A-R strobe plates (15cd). The conference centre had Edwards 439D-10AWC vibrating bells (10” gong), also on 403-5A-R strobe plates (15cd).

Initiating Devices

Pull Stations

The pull stations were a mix of Edwards 275-C111 conventional single-action pull stations and Mirtone 73303 conventional single-action pull stations.

Automatic Detection Devices

Unknown.