Renfrew Educational Services Bowness Centre: Difference between revisions

From FireAlarmPedia
(Overhauled the page. Seems that Mircom's 400 series is losing out to the L-series.)
Line 7: Line 7:
| FACP: Mircom FX-2000 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2020<br />Year Opened: 1998
| FACP: Mircom FX-2000 <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />Date of last known Upgrade: 2020<br />Year Opened: 1998
|}
|}
'''Renfrew Educational Services''' is a special needs school, with many locations. This page counts for the Bowness centre. It was built as a large house in 1998, and bought by Renfrew and converted to a school that next year (1999). The fire alarm system is not original, it was replaced in 2020.
'''Renfrew Educational Services''' is a special needs school, with many locations. This particular school is located in Bowness, in Northwest Calgary. It was built as a large house in 1998, and bought by Renfrew and converted to a school that next year (1999). The fire alarm system is not original, it was replaced in 2020.
 
== System Specifications (2020-present) ==
== System Specifications (2020-present) ==
==== FACP ====
==== FACP ====
 
The school is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located near the main entrance.  The system runs Mircom's Advanced addressable protocol, and does code 3 in alarm.
The fire alarm panel is a Mircom FX-2000. It is located at the entrance of the school, and was installed in 2020 as a replacement for an older panel, which is unknown.
 
==== Notification Appliances ====
==== Notification Appliances ====
 
All notification appliances are System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, bilingual).
The notification appliances consist of System Sensor "L-Series" P2RLA (red, wall, bilingual) horn/strobes. They were installed in 2020 as a replacement for older horns, which were unknown at this time.
 
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
 
All pull stations are Mircom MS-401AP addressable single-action pull stations.
The pull stations consist of Mircom MS-401 tab pull stations.
 
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
 
There are Mircom MIX-2251AP addressable photoelectric smoke detectors throughout the building.
The automatic detection devices consist of Mircom MIX-2251AP addressable photoelectric smoke detectors, installed in 2020.

Revision as of 10:19, 15 March 2022

System Specifications
FACP: Mircom FX-2000
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
Date of last known Upgrade: 2020
Year Opened: 1998

Renfrew Educational Services is a special needs school, with many locations. This particular school is located in Bowness, in Northwest Calgary. It was built as a large house in 1998, and bought by Renfrew and converted to a school that next year (1999). The fire alarm system is not original, it was replaced in 2020.

System Specifications (2020-present)

FACP

The school is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located near the main entrance. The system runs Mircom's Advanced addressable protocol, and does code 3 in alarm.

Notification Appliances

All notification appliances are System Sensor "L-Series" P2RLA horn/strobes (red, wall-mount, bilingual).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AP addressable single-action pull stations.

Automatic Detection Devices

There are Mircom MIX-2251AP addressable photoelectric smoke detectors throughout the building.