| FACP: Edwards EST3 <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 70VRMS (audible) <br> 24VDC (visual) <br /> System Coding: 20BPM chime (first stage) <br> March Time Chime (GA) <br> Strobes Synchronized: Yes <br />Date of last known Upgrade: 2010s <br />Year Opened: 1974/2000 | |||
|} | |||
'''Telus Convention Centre''' is a large convention centre located in Downtown Calgary, Alberta. This building commonly holds galas and expos. During the COVID-19 pandemic, the centre was used as a mass vaccination clinic, the largest in Alberta. The centre has two buildings. The South Building was opened in 1974, and the North Building opened its doors in 2000. The building was fully renovated in 2000, and received a new fire alarm system that same year. The system is serviced by Viking Fire Protection Inc. | |||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The buildings are protected by an EST3 addressable fire alarm system. | The buildings are protected by an Edwards EST3 addressable fire alarm system. The panel is located at the main entrance. The system runs EST’s Signature-series addressable protocol, and is configured for two stage operation. It does a 20BPM chime in first stage, followed by march time in general alarm. | ||
=====Annunciators===== | =====Annunciators===== | ||
There are several EST3-LCDANN annunciators throughout the facility. | There are several EST3-LCDANN annunciators throughout the facility. The one in the front desk has an EST 3-REMICA mic on it. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
Most notification appliances are Edwards 965-7A-4RW speaker/strobes (white, | Most notification appliances are Edwards 965-7A-4RW speaker/strobes (white, ceiling-mount, 4”, 15/75cd). One hallway has Edwards 965-5A-4RW speaker/strobes (white, ceiling-mount, 15cd, 4") on the walls. The North Building hallways have Edwards “Integrity” 202-5A-T remote strobes (red, wall-mount, 15cd) for extra coverage, as well as 965-1A-4RW (white, 4" ceiling mount) speakers for additional sound coverage. The main conference rooms have Edwards “Integrity” 757-7A-SS70W speaker/strobes (white, ceiling-mount, 15/75cd, 70.7V). | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are EST SIGA-270P addressable single-action pull stations. | All pull stations are EST SIGA-270P addressable single-action pull stations, most of which are original. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the facility. | There are EST SIGA-PS addressable photoelectric smoke detectors throughout the facility. |
Revision as of 16:33, 18 November 2022
System Specifications |
---|
FACP: Edwards EST3 FACP Location: Main Entrance System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 70VRMS (audible) 24VDC (visual) System Coding: 20BPM chime (first stage) March Time Chime (GA) Strobes Synchronized: Yes Date of last known Upgrade: 2010s Year Opened: 1974/2000 |
Telus Convention Centre is a large convention centre located in Downtown Calgary, Alberta. This building commonly holds galas and expos. During the COVID-19 pandemic, the centre was used as a mass vaccination clinic, the largest in Alberta. The centre has two buildings. The South Building was opened in 1974, and the North Building opened its doors in 2000. The building was fully renovated in 2000, and received a new fire alarm system that same year. The system is serviced by Viking Fire Protection Inc.
System Specifications
FACP
The buildings are protected by an Edwards EST3 addressable fire alarm system. The panel is located at the main entrance. The system runs EST’s Signature-series addressable protocol, and is configured for two stage operation. It does a 20BPM chime in first stage, followed by march time in general alarm.
Annunciators
There are several EST3-LCDANN annunciators throughout the facility. The one in the front desk has an EST 3-REMICA mic on it.
Notification Appliances
Most notification appliances are Edwards 965-7A-4RW speaker/strobes (white, ceiling-mount, 4”, 15/75cd). One hallway has Edwards 965-5A-4RW speaker/strobes (white, ceiling-mount, 15cd, 4") on the walls. The North Building hallways have Edwards “Integrity” 202-5A-T remote strobes (red, wall-mount, 15cd) for extra coverage, as well as 965-1A-4RW (white, 4" ceiling mount) speakers for additional sound coverage. The main conference rooms have Edwards “Integrity” 757-7A-SS70W speaker/strobes (white, ceiling-mount, 15/75cd, 70.7V).
Initiating Devices
Pull Stations
All pull stations are EST SIGA-270P addressable single-action pull stations, most of which are original.
Automatic Detection Devices
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the facility.