More actions
No edit summary |
(Fixed some spelling mistakes as well as adding some new stuff) |
||
Line 22: | Line 22: | ||
|6 Zones | |6 Zones | ||
|2 NACs | |2 NACs | ||
| | |Continuous | ||
| | | | ||
|24VDC | |24VDC | ||
Line 38: | Line 38: | ||
|4 Zones | |4 Zones | ||
|2 NACs | |2 NACs | ||
| | |Continuous | ||
| | | | ||
|24VFWR | |24VFWR | ||
Line 44: | Line 44: | ||
|None | |None | ||
|1984 | |1984 | ||
| | |In a box of stuff that I misplaced years ago | ||
|Shane | |Shane | ||
(Sprouse) | (Sprouse) | ||
Line 54: | Line 54: | ||
|1 Zone | |1 Zone | ||
|1 NAC | |1 NAC | ||
| | |Continuous | ||
| | | | ||
|24VFWR | |24VFWR | ||
Line 69: | Line 69: | ||
|1 Zone | |1 Zone | ||
|1 NAC | |1 NAC | ||
| | |Continuous | ||
| | | | ||
|24VFWR | |24VFWR | ||
Line 103: | Line 103: | ||
|1000 | |1000 | ||
|8 NACs | |8 NACs | ||
|Continuous, Temporal, Custom | |Continuous, Temporal, Coder (Custom) | ||
| | |16.5 A | ||
|24VFWR | |24VFWR | ||
|120VAC | |120VAC | ||
|Genesis | |Genesis | ||
| | |2019 | ||
|My favourite panel. | |My favourite panel. | ||
Line 115: | Line 115: | ||
|Carl | |Carl | ||
(Legacy) | (Legacy) | ||
|- | |||
|IBM | |||
4201-2 | |||
(Soon to be obtained) | |||
| | |||
|Coded | |||
|N/A | |||
|2 | |||
|4-4 | |||
| | |||
|120VAC | |||
|120VAC | |||
|Npne | |||
|1940s | |||
|Will be my oldest panel by far | |||
|Glenn James | |||
(Old School Fire Alarms) | |||
|} | |} | ||
=== Notification Appliances === | === Notification Appliances === | ||
Line 228: | Line 246: | ||
Conventional | Conventional | ||
| | |Unknown | ||
| | | | ||
|AdenK2333 | |AdenK2333 | ||
|- | |- | ||
|Couch | |Couch | ||
F1GG "Chevron | F1GG "Chevron" | ||
| | | | ||
|1 | |1 | ||
Line 240: | Line 258: | ||
Conventional | Conventional | ||
| | |Unknown | ||
|Broke from being slammed | |Broke from being slammed | ||
|Shane (Sprouse) | |Shane (Sprouse) | ||
|- | |- | ||
|Notifier | |Notifier | ||
NBG12LX | |||
| | | | ||
|1 | |1 | ||
Line 252: | Line 270: | ||
Conventional | Conventional | ||
| | |Unknown | ||
| | | | ||
|Unknown | |Unknown | ||
|- | |- | ||
Line 264: | Line 282: | ||
Conventional | Conventional | ||
| | |Unknown | ||
| | | | ||
|YYCFireAlarmNimrod | |YYCFireAlarmNimrod | ||
Line 276: | Line 294: | ||
Conventional | Conventional | ||
| | |Unknown | ||
| | | | ||
|YYCFireAlarmNimrod | |YYCFireAlarmNimrod | ||
Line 332: | Line 350: | ||
|Rate of Rise Heat | |Rate of Rise Heat | ||
Addressable | Addressable | ||
| | |Unknown | ||
| | | | ||
|Unknown | |Unknown | ||
|- | |||
|Notifier | |||
FSP-851 | |||
| | |||
|1 | |||
|Photo Smoke | |||
Addressable | |||
|2018? | |||
|Came new old stock | |||
|Phuntington | |||
|- | |||
|Notifier | |||
FSP-951 | |||
| | |||
|1 | |||
|Photo Smoke | |||
Addressable | |||
|2022 | |||
|Came brand new | |||
|Phuntington | |||
|} | |} |
Revision as of 11:24, 5 April 2022
Panels (FACP)
Model | Image | Type | Zone/Point Capacity | NACs | Coding Options | Power Supply | NAC Voltage | System Line Voltage | Synchronization Support | Manufacturing Date | Notes | Origin |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Edwards
2280 |
Conventional | 6 Zones | 2 NACs | Continuous | 24VDC | 120VAC | None | 1979 | My oldest panel | Carl
(Legacy) | ||
Fire Lite
Miniscan 112 |
Conventional | 4 Zones | 2 NACs | Continuous | 24VFWR | 120VAC | None | 1984 | In a box of stuff that I misplaced years ago | Shane
(Sprouse) | ||
Notifier/Emhart
Unknown Model |
Conventional | 1 Zone | 1 NAC | Continuous | 24VFWR | 120VAC | None | Unknown | None of the LEDs work | Shane (Sprouse) | ||
Mirtone
70605 |
Conventional | 1 Zone | 1 NAC | Continuous | 24VFWR | 120VAC | None | Unknown | My Rarest panel. I'm the only collector to own one | Carl (Legacy) | ||
Notifier
AFP-200C |
Addressable | 99 Points (Modules)
99 Points (Detectors) |
4 NACs | Continuous, Temporal, 120BPM, California | 24VDC | 120VAC | System Sensor, Wheelock, Gentex | 2002 | Carl
(Legacy) | |||
EST
IO-1000 |
Addressable | 1000 | 8 NACs | Continuous, Temporal, Coder (Custom) | 16.5 A | 24VFWR | 120VAC | Genesis | 2019 | My favourite panel.
|
Carl
(Legacy) | |
IBM
4201-2 (Soon to be obtained) |
Coded | N/A | 2 | 4-4 | 120VAC | 120VAC | Npne | 1940s | Will be my oldest panel by far | Glenn James
(Old School Fire Alarms) |
Notification Appliances
Model Number | Images | Quantity | Type | Product Line | Voltage | Strobe Intensity | Sound Output | Manufacturing Date | Notes | Origin |
---|---|---|---|---|---|---|---|---|---|---|
Edwards
439D-6AWC |
1 | Vibrating Bell | 24VDC | 98db | Unknown | |||||
Simplex
2901 2723 |
3 | Motor Bell | 24VDC | Unkown | 2012 | |||||
Some old horn | 1 | Mechanical horn | 12VAC | 133db | Unknown | LOUD!!!!
looks looks like it could have a projector |
||||
EST
G1-HDVM |
1 | Horn/Strobe | Genesis | 24VDC | Multi CD | 103db | Unkown | AdenK2333 | ||
EST
G1-VM |
2 | Remote Strobe | Genesis | 24VDC | Multi CD | 2017 | Carl (Lagacy) | |||
Wheelock MT-241575W | 1 | Horn/Storbe | 24VDC | 15/75 CD | Varying | Unknown | AdenK2333 |
Pull Stations
Model Number | Image | Quantity | Type | Manufacturing
Date |
Notes | Origin |
---|---|---|---|---|---|---|
Simplex
4251-20 |
1 | Single Action
Single Stage Conventional |
Unknown | AdenK2333 | ||
Couch
F1GG "Chevron" |
1 | Single Action
Single Stage Conventional |
Unknown | Broke from being slammed | Shane (Sprouse) | |
Notifier
NBG12LX |
1 | Dual Action
Single Stage Conventional |
Unknown | Unknown | ||
Notifier
LNG-1R |
1 | Dual Action
Single Stage Conventional |
Unknown | YYCFireAlarmNimrod | ||
Notifier
MPS-950B |
1 | Single Action
Single Stage Conventional |
Unknown | YYCFireAlarmNimrod | ||
Edwards
270-SPOW |
1 | Single Action
Single Stage Conventional |
Switch is no longer functional. Screw is so stripped its unusable | Unknown |
Automatic Detectors
Model Number | Image | Quantity | Type | Manufacturing
Date |
Notes | Origin |
---|---|---|---|---|---|---|
Edwards
C2M-PD |
1 | Photo Smoke
Conventional 2-Wire |
Unknown | YYCFireAlarmNimrod | ||
EST
SIGA-PD |
1 | Photo Smoke
Addressable |
2017 | Came brand new | EST Tech | |
Vigilant
V-HRD |
1 | Rate of Rise Heat
Addressable |
Unknown | Unknown | ||
Notifier
FSP-851 |
1 | Photo Smoke
Addressable |
2018? | Came new old stock | Phuntington | |
Notifier
FSP-951 |
1 | Photo Smoke
Addressable |
2022 | Came brand new | Phuntington |