==System Specifications== | ==System Specifications== | ||
===FACP=== | ===FACP=== | ||
The | The station is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown, but the model is confirmed due to the size and age of building. The system runs Notifier's FlashScan addressable protocol, and the system coding is Temporal. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
The alarms consist of System Sensor "SpectrAlert Advance" P2RA (red, 2-wire) horn/strobes. | The alarms consist of System Sensor "SpectrAlert Advance" P2RA (red, 2-wire) horn/strobes. | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
Line 21: | Line 20: | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout. | There are Notifier FSP-951A addressable photoelectric smoke detectors throughout. | ||
== References == | == References == | ||
<references /> | <references /> |
Revision as of 12:17, 15 November 2022
System Specifications |
---|
FACP: Notifier NFS-320C FACP Location: Unknown System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes Date of last known Upgrade: 2011 Year Opened: 1985 |
Whitehorn Station is a centre-loading train station on the Blue Line of the Calgary Transit LRT in Calgary, AB. Originally built in 1985 but underwent major renovations in 2011 which added an at-grade crossing on the south end at Whitehorn Drive NE<ref>http://web.archive.org/web/20120229150759/http://www.calgarytransit.com/pdf/Whitehorn_LRT_2010_03_10.pdf</ref>. The current system is from 2011.
System Specifications
FACP
The station is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown, but the model is confirmed due to the size and age of building. The system runs Notifier's FlashScan addressable protocol, and the system coding is Temporal.
Notification Appliances
The alarms consist of System Sensor "SpectrAlert Advance" P2RA (red, 2-wire) horn/strobes.
Initiating Devices
Pull Stations
The pull stations are all Notifier NBG-12LX (addressable, dual-action) pull stations.
Automatic Detection Devices
There are Notifier FSP-951A addressable photoelectric smoke detectors throughout.