Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

GMC Stadium: Difference between revisions

From FireAlarmPedia
No edit summary
(System coding is confirmed. BUT ITS THE WRONG CODING!!!!!)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS-320C <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: 20BPM (First Stage) <br> Temporal (GA) <br />Date of last known Upgrade: 2013 <br />Year Opened: 1974
| FACP: Notifier NFS2-3030C<br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: 20BPM (First Stage) <br> 120BPM March Time (GA) <br />Date of last known Upgrade: 2013 <br />Year Opened: 1974
|}
|}
 
'''GMC Stadium''', formerly known as the Stampede Grandstand, is an outdoor stadium located at 2200 Stampede Trail Southeast, in Calgary, Alberta, Canada. The stadium hosts the Calgary Stampede rodeo, chuckwagon races, and grandstand shows. The stadium has a seating capacity of 17,000, with standing room space for 8,000, bringing the total capacity to 25,000. The stadium opened in 1974, and the fire alarm system is from the 2000s-2010s.
'''GMC Stadium''', formerly known as the Stampede Grandstand, is an outdoor stadium located at 2200 Stampede Trail Southeast, in Calgary, Alberta, Canada. The stadium hosts the Calgary Stampede rodeo, chuckwagon races, and grandstand shows. The stadium has a seating capacity of 17,000, with standing room space for 8,000, bringing the total capacity to 25,000. The stadium opened in 1974, and the fire alarm system is from the 2000s-2010s.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown, and was installed as an emergency replacement due to flooding. The system runs Notifier’s CLIP addressable protocol, and is configured for two-stage operation. First stage coding is 20BPM, followed by temporal in general alarm.
The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown, and was installed as an emergency replacement due to flooding. The system runs Notifier’s CLIP addressable protocol, and is configured for two-stage operation. First stage coding is 20BPM, followed by 120BPM march time in general alarm.
 
====Notification Appliances====
====Notification Appliances====
All indoor notification appliances are System Sensor “SpectrAlert” P1224MCA horn/strobes (red, wall-mount). The seating area has System Sensor P1224MCKA weatherproof horn/strobes (red, wall-mount).
All indoor notification appliances are System Sensor “SpectrAlert” P1224MCA horn/strobes (red, wall-mount). The seating area has System Sensor P1224MCKA weatherproof horn/strobes (red, wall-mount). These are set to electromechanical horn.
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
Most pull stations are Notifier NFM-950KB conventional two-stage single-action pull stations. There are Notifier MPS-950KB conventional two-stage single-action pull stations as deficiency replacements in some areas, as well as a Notifier N-MPS-2A addressable two-stage single-action pull station by the second floor stairway, also a deficiency replacement. All NFM stations are wired to Notifier MMX-101A addressable modules; all MPS stations are wired to Notifier FMM-101A addressable modules. All modules are mounted behind each station, and there are two per station.
Most pull stations are Notifier NFM-950KB conventional two-stage single-action pull stations. There are Notifier MPS-950KB conventional two-stage single-action pull stations as deficiency replacements in some areas, as well as a Notifier N-MPS-2A addressable two-stage single-action pull station by the second floor stairway, also a deficiency replacement. All NFM stations are wired to Notifier MMX-101A addressable modules; all MPS stations are wired to Notifier FMM-101A addressable modules. All modules are mounted behind each station, and there are two per station.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
[[]
[[]

Revision as of 23:36, 15 November 2023

System Specifications
FACP: Notifier NFS2-3030C
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: 20BPM (First Stage)
120BPM March Time (GA)
Date of last known Upgrade: 2013
Year Opened: 1974

GMC Stadium, formerly known as the Stampede Grandstand, is an outdoor stadium located at 2200 Stampede Trail Southeast, in Calgary, Alberta, Canada. The stadium hosts the Calgary Stampede rodeo, chuckwagon races, and grandstand shows. The stadium has a seating capacity of 17,000, with standing room space for 8,000, bringing the total capacity to 25,000. The stadium opened in 1974, and the fire alarm system is from the 2000s-2010s.

System Specifications

FACP

The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown, and was installed as an emergency replacement due to flooding. The system runs Notifier’s CLIP addressable protocol, and is configured for two-stage operation. First stage coding is 20BPM, followed by 120BPM march time in general alarm.

Notification Appliances

All indoor notification appliances are System Sensor “SpectrAlert” P1224MCA horn/strobes (red, wall-mount). The seating area has System Sensor P1224MCKA weatherproof horn/strobes (red, wall-mount). These are set to electromechanical horn.

Initiating Devices

Pull Stations

Most pull stations are Notifier NFM-950KB conventional two-stage single-action pull stations. There are Notifier MPS-950KB conventional two-stage single-action pull stations as deficiency replacements in some areas, as well as a Notifier N-MPS-2A addressable two-stage single-action pull station by the second floor stairway, also a deficiency replacement. All NFM stations are wired to Notifier MMX-101A addressable modules; all MPS stations are wired to Notifier FMM-101A addressable modules. All modules are mounted behind each station, and there are two per station.

Automatic Detection Devices

None noticed. [[]