| FACP: Mircom FX-2000 <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: 2022 <br />Year Opened: 2002
| FACP: Mircom FX-2000 <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, Mircom <br />Date of last known Upgrade: 2022 <br />Year Opened: 2002
|}
|}
 
'''LOCAL Public Eatery''' is a restaurant chain owned by JOEY Restaurants. This particular restaurant is located at 1820 99 Street Northwest, in the South Edmonton Common shopping area of Edmonton, Alberta, Canada. The building opened in 2002 as OPM Asian Bistro, and became LOCAL Public Eatery in approximately 2011. The fire alarm system was upgraded in 2021.
'''LOCAL Public Eatery''' is a restaurant chain owned by JOEY Restaurants. This particular restaurant is located at 1820 99 Street Northwest, in the South Edmonton Common shopping area of Edmonton, Alberta, Canada. The building opened in 2002 as OPM Asian Bistro, and became LOCAL Public Eatery in approximately 2011. The fire alarm system was upgraded in 2021.
 
==System Specifications (2021-present)==
==System Specifications (2021-present)==
====FACP====
====FACP====
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s “Advanced” addressable protocol, and the system coding is temporal.
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s “Advanced” addressable protocol, and the system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd).
All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Mircom MS-401AP addressable single-action pull stations.
All pull stations are Mircom MS-401AP addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
==System Specifications (2002-2021)==
==System Specifications (2002-2021)==
====FACP====
====FACP====
The building was protected by a Mircom FX-2000 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Mircom’s CLIP addressable protocol, and the system coding was temporal. This panel was replaced in 2021 with a newer Mircom FX-2000.
The building was protected by a Mircom FX-2000 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Mircom’s CLIP addressable protocol, and the system coding was temporal. This panel was replaced in 2021 with a newer Mircom FX-2000.
 
====Notification Appliances====
====Notification Appliances====
All notification appliances were Mircom “Select-A-Horn/Strobe” FHS-240R horn/strobes (red, wall-mount, set to broadband/15cd).
All notification appliances were Mircom “Select-A-Horn/Strobe” FHS-240R horn/strobes (red, wall-mount, set to broadband/15cd).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations were Mircom MS-401AD addressable single-action pull stations.
All pull stations were Mircom MS-401AD addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed.
None noticed.
[[]
[[]
[[Category:Restaurant]
[[Category:Restaurant]
[[Category:Edmonton]]
[[Category:Restaurants]]

Revision as of 17:29, 25 May 2024

System Specifications
FACP: Mircom FX-2000
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Mircom
Date of last known Upgrade: 2022
Year Opened: 2002

LOCAL Public Eatery is a restaurant chain owned by JOEY Restaurants. This particular restaurant is located at 1820 99 Street Northwest, in the South Edmonton Common shopping area of Edmonton, Alberta, Canada. The building opened in 2002 as OPM Asian Bistro, and became LOCAL Public Eatery in approximately 2011. The fire alarm system was upgraded in 2021.

System Specifications (2021-present)

FACP

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom’s “Advanced” addressable protocol, and the system coding is temporal.

Notification Appliances

All notification appliances are Mircom FHS-400-RR horn/strobes (red, wall-mount, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AP addressable single-action pull stations.

Automatic Detection Devices

None noticed.

System Specifications (2002-2021)

FACP

The building was protected by a Mircom FX-2000 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Mircom’s CLIP addressable protocol, and the system coding was temporal. This panel was replaced in 2021 with a newer Mircom FX-2000.

Notification Appliances

All notification appliances were Mircom “Select-A-Horn/Strobe” FHS-240R horn/strobes (red, wall-mount, set to broadband/15cd).

Initiating Devices

Pull Stations

All pull stations were Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices

None noticed. [[] [[Category:Restaurant]