'''Motel 6''' is a chain of budget motels. This particular motel is located at 2800 Greenway Drive, in Jackson, Mississippi, USA. The hotel opened in 1995, and the fire alarm system is original. | '''Motel 6''' is a chain of budget motels. This particular motel is located at 2800 Greenway Drive, in Jackson, Mississippi, USA. The hotel opened in 1995, and the fire alarm system is original. | ||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The building is protected by an Edwards EST1 conventional fire alarm system. The panel is located behind the front desk. The system coding is likely continuous. | The building is protected by an Edwards EST1 conventional fire alarm system. The panel is located behind the front desk. The system coding is likely continuous. | ||
====Notification Appliance==== | ====Notification Appliance==== | ||
There are Edwards 792-7A-006 horn/strobes (red, wall-mount, 15/75cd) throughout the common areas. There are no fire alarm devices in the guest rooms. | There are Edwards 792-7A-006 horn/strobes (red, wall-mount, 15/75cd) throughout the common areas. There are no fire alarm devices in the guest rooms. | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Edwards 276B-1110 conventional single-action pull stations. | All pull stations are Edwards 276B-1110 conventional single-action pull stations. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
To be added later. | To be added later. | ||
[[Category:Hotels]] | |||
[[Category:Mississippi]] |
Latest revision as of 20:58, 25 May 2024
System Specifications |
---|
FACP: Edwards EST1 FACP Location: Behind Front Desk System Type: Conventional System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Continuous? Strobes Synchronized: No Date of last known Upgrade: N/A Year Opened: 1995 |
Motel 6 is a chain of budget motels. This particular motel is located at 2800 Greenway Drive, in Jackson, Mississippi, USA. The hotel opened in 1995, and the fire alarm system is original.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by an Edwards EST1 conventional fire alarm system. The panel is located behind the front desk. The system coding is likely continuous.
Notification Appliance[edit | edit source]
There are Edwards 792-7A-006 horn/strobes (red, wall-mount, 15/75cd) throughout the common areas. There are no fire alarm devices in the guest rooms.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Edwards 276B-1110 conventional single-action pull stations.
Automatic Detection Devices[edit | edit source]
To be added later.