| FACP: Edwards EST4 <br />FACP Location: Main Entrance <br>System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br>System Coding: 20BPM (First Stage) <br>Temporal (GA) <br>Date of last known Upgrade: May 2023<br />Year Opened: 1981
| FACP: Edwards EST4 <br />FACP Location: Main Entrance <br>System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC<br>System Coding: 20BPM (Alert) <br>Temporal (Alarm) <br>Date of last known Upgrade: May 2023<br />Year Opened: 1981
|}
|}
 
'''Village Square Leisure Centre''' (also known as Pepsi Thunder) is an indoor leisure centre located at 2623 56 Street Northeast, in Calgary, Alberta, Canada. The facility is owned and operated by the City of Calgary. The facility has a large waterpark with a "Thunder Run" waterslide, a wave pool, dive tank, and splash area. The facility also has a fitness centre, several gymnasiums, two NHL-sized arenas, and a Calgary Public Library branch. The building opened in 1981, and was renovated in 2009. The fire alarm system was upgraded in 2009, and again in May of 2023.
'''Village Square Leisure Centre''' (also known as Pepsi Thunder) is an indoor leisure centre located at 2623 56 Street Northeast, in Calgary, Alberta, Canada. The facility is owned and operated by the City of Calgary. The facility has a large waterpark with a "Thunder Run" waterslide, a wave pool, dive tank, and splash area. The facility also has a fitness centre, several gymnasiums, two NHL-sized arenas, and a Calgary Public Library branch. The building opened in 1981, and was renovated in 2009. The fire alarm system was upgraded in 2009, and again in May of 2023.
 
==System Specifications (May 2023-present)==
==System Specifications (May 2023-present)==
====FACP====
====FACP====
The building is protected by an Edwards EST4 addressable fire alarm system. The panel is located to the left of the main entrance, across from the customer service desk. The system runs Edwards' Signature addressable protocol, and is configured for two-stage operation. First stage coding is 20BPM, followed by temporal in general alarm.
The building is protected by an Edwards EST4 addressable fire alarm system. The panel is located to the left of the main entrance, across from the customer service desk. The system runs Edwards' Signature addressable protocol, and is configured for two-stage operation. Alert signal coding is 20BPM, followed by temporal in for the evacuation signal.  
 
====Notification Appliances====
====Notification Appliances====
Most notification appliances are Edwards 439D-10AWC vibrating bells (10" gong), mostly mounted behind metal grilles. These have Edwards "Genesis" G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd) next to them in the library, and are mounted remotely in other areas. Some areas, such as the waterslide tower, have Edwards 439D-6AWC motor bells (6" gong). These were installed in 2009.
Most notification appliances are Edwards 439D-10AWC vibrating bells (10" gong), mostly mounted behind metal grilles. These have Edwards "Genesis" G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd) next to them in the library, and are mounted remotely in other areas. Some areas, such as the waterslide tower, have Edwards 439D-6AWC motor bells (6" gong). These were installed in 2009.
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Edwards SIGA-270P addressable two-stage single-action pull stations. Most stations are mounted under STI "Stopper II" covers.
All pull stations are Edwards SIGA-270P addressable two-stage single-action pull stations. Most stations are mounted under STI "Stopper II" covers.
 
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed. The building is equipped with a sprinkler system.
None noticed. The building is equipped with a sprinkler system.
 
====Modules====
====Modules====
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
|-
|-
Line 33: Line 26:
|  
|  
|-
|-
| FACP: EST QuickStart QS4 <br />FACP Location: Main Entrance <br>System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: 20BPM (First Stage) <br>Temporal (GA) <br>Year Installed: 2009 <br />Year Decommissioned: 2023
| FACP: EST QuickStart QS4 <br />FACP Location: Main Entrance <br>System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: 20BPM (Alert) <br>Temporal (Alarm) <br>Year Installed: 2009 <br />Year Decommissioned: 2023
|}
|}
==Former System Specifications (2009-May 2023)==
==Former System Specifications (2009-May 2023)==
==== FACP ====
==== FACP ====
The building was protected by an EST Quickstart QS4 addressable fire alarm system. The panel was located next to the main entrance, across from the admissions desk. The system ran EST's Signature-series addressable protocol, and was configured for two-stage operation. First stage coding was 20BPM, followed by 120BPM in general alarm.
The building was protected by an EST Quickstart QS4 addressable fire alarm system. The panel was located next to the main entrance, across from the admissions desk. The system ran EST's Signature-series addressable protocol, and was configured for two-stage operation. Alert signal coding was 20BPM, followed by 120BPM for the evacuation signal.
 
==== Notification Appliances ====
==== Notification Appliances ====
Most notification appliances were Edwards 439D-10AWC vibrating bells (10" gong), mounted behind metal grilles. The library also had EST "Genesis" G1R-VM remote strobes (red, wall-mount) mounted sideways next to the bells. Some areas, such as the waterslide tower, had Edwards 439D-6AWC vibrating bells (6" gong), for extra coverage. All notification appliances are still in use on the current system.
Most notification appliances were Edwards 439D-10AWC vibrating bells (10" gong), mounted behind metal grilles. The library also had EST "Genesis" G1R-VM remote strobes (red, wall-mount) mounted sideways next to the bells. Some areas, such as the waterslide tower, had Edwards 439D-6AWC vibrating bells (6" gong), for extra coverage. All notification appliances are still in use on the current system.
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations were EST SIGA-270 addressable single-action pull stations. The system goes into general alarm if two devices are activated.
All pull stations were EST SIGA-270 addressable single-action pull stations. The system goes into general alarm if two devices are activated.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
None noticed.
None noticed.
[[Category:Facilities]]
[[Category:Facilities]]

Revision as of 22:58, 20 December 2023

System Specifications
FACP: Edwards EST4
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: 20BPM (Alert)
Temporal (Alarm)
Date of last known Upgrade: May 2023
Year Opened: 1981

Village Square Leisure Centre (also known as Pepsi Thunder) is an indoor leisure centre located at 2623 56 Street Northeast, in Calgary, Alberta, Canada. The facility is owned and operated by the City of Calgary. The facility has a large waterpark with a "Thunder Run" waterslide, a wave pool, dive tank, and splash area. The facility also has a fitness centre, several gymnasiums, two NHL-sized arenas, and a Calgary Public Library branch. The building opened in 1981, and was renovated in 2009. The fire alarm system was upgraded in 2009, and again in May of 2023.

System Specifications (May 2023-present)

FACP

The building is protected by an Edwards EST4 addressable fire alarm system. The panel is located to the left of the main entrance, across from the customer service desk. The system runs Edwards' Signature addressable protocol, and is configured for two-stage operation. Alert signal coding is 20BPM, followed by temporal in for the evacuation signal.

Notification Appliances

Most notification appliances are Edwards 439D-10AWC vibrating bells (10" gong), mostly mounted behind metal grilles. These have Edwards "Genesis" G1R-VM remote strobes (red, wall-mount, no marking, set to 15cd) next to them in the library, and are mounted remotely in other areas. Some areas, such as the waterslide tower, have Edwards 439D-6AWC motor bells (6" gong). These were installed in 2009.

Initiating Devices

Pull Stations

All pull stations are Edwards SIGA-270P addressable two-stage single-action pull stations. Most stations are mounted under STI "Stopper II" covers.

Automatic Detection Devices

None noticed. The building is equipped with a sprinkler system.

Modules

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

Former System Specifications
FACP: EST QuickStart QS4
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: 20BPM (Alert)
Temporal (Alarm)
Year Installed: 2009
Year Decommissioned: 2023

Former System Specifications (2009-May 2023)

FACP

The building was protected by an EST Quickstart QS4 addressable fire alarm system. The panel was located next to the main entrance, across from the admissions desk. The system ran EST's Signature-series addressable protocol, and was configured for two-stage operation. Alert signal coding was 20BPM, followed by 120BPM for the evacuation signal.

Notification Appliances

Most notification appliances were Edwards 439D-10AWC vibrating bells (10" gong), mounted behind metal grilles. The library also had EST "Genesis" G1R-VM remote strobes (red, wall-mount) mounted sideways next to the bells. Some areas, such as the waterslide tower, had Edwards 439D-6AWC vibrating bells (6" gong), for extra coverage. All notification appliances are still in use on the current system.

Initiating Devices

Pull Stations

All pull stations were EST SIGA-270 addressable single-action pull stations. The system goes into general alarm if two devices are activated.

Automatic Detection Devices

None noticed.